INSTALLATION MANUAL

1/9

INSTALLATION MANUAL

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available via QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to 

electrostatic discharges. Take appropriate measures during any operation.

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at risk.

The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

DOCUMENTATION

Série S311D-XX-L / S311D-XX-H

Содержание S311D

Страница 1: ...opriate measures during any operation PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user s safety at risk The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment The warranty shall become null and void in the event of improper use or tampering with the module or...

Страница 2: ... the parameters of the instrument can be set via the Programming Menu or RS485 via optional board The alarm thresholds can also be set quickly via the specific Quick Alarm Menu The dedicated Easy Setup software for programming configuring the module was also developed see www seneca it Retransmission mode The instrument accepts the following retransmission modes Analogue output The measurement of ...

Страница 3: ...NS Removable screw terminals 3 5 mm 5 08 mm pitch DIGITAL INPUT Type Reed Npn 2 wires npn 24 V 3 wires or pnp 24 V 3 wires NAMUR Photoelectric Astra Hall 24 V input TTL Variable reluctance Absorbed current max 7 mA Vmax 28 Vdc Sensor power supply 17 Vdc Frequency band 0 00014 Hz 10 kHz Frequency resolution 0 05 ANALOGUE OUTPUT Applied current 0 20 mA max load resistance 500 W Voltage 0 10 V min lo...

Страница 4: ...increased by one unit at each rising edge of the digital input Decreasing it is decreased by one unit at each rising edge of the digital input Once the maximum or minimum limit is reached counting restarts from zero It is also possible to set a reduction ratio by which to divide the totalizer value the resulting value will then be displayed Reset can also take place in the following three ways Fro...

Страница 5: ...100 mV The internal power supply for the sensors equal to 17 Vdc is available at terminals 7 and 10 03 04 05 06 VOLTAGE V 03 04 05 06 APPLIED CURRENT A Active output already powered to be connected to passive inputs 03 04 05 06 EXTERNAL POWER SUPPLY Passive output not powered to be connected to active inputs DIGITAL OUTPUT 03 04 05 06 I OPTIONAL BOARD CONNECTIONS R I max V R 50 mA I 21 20 19 RS485...

Страница 6: ...mposed by DPIN Minimum value 0 Max value depending on the display 4 11 4 7 digits 9999 without decimal point 6 8 digits 10000 without decimal point 1000 Hz dpIn Position of decimal point in HI F 0 no decimal point e g 00009999 1 first digit e g 0000999 9 2 second decimal point e g 000099 99 3 third decimal point e g 00009 999 4 fourth decimal digit e g 0000 9999 only for 6 and 8 digit models 0 Dec...

Страница 7: ... not active rLY1 Relay 1 N O or N C Relay operation 0 relay normally open N O 1 relay normally closed N C 0 N O rLY2 Relay 2 N O or N C 0 N O PARAMETERS TO SET FROM THE MENU O U t LO t Frequency display value associated with the minimum output value Limits for scaling the retransmitted output see TABLE1 Decimal point imposed by dP d 0 HI t Frequency display value associated with the maximum output...

Страница 8: ...a flash card and after a few moments reset the module SUMMARY OF BUTTON ACTIONS in display mode Below is a summary of the actions that can be performed from the button starting from the display phase not programming In order for the actions to be carried out the pressure on the buttons must last a few seconds ERROR REPORTING Any errors are also shown directly on the display Below are the possible ...

Страница 9: ...ange HYS1 Change tyP1 Change rLy1 Change HI d Change dp_d Change FILT Change AVI Change HI F Change DPIN Change IrES Change PASS PASS HI F dp_D FILt FAHR FAHR FAHR AVI Typ1 Typ2 FAHR FAHR RLy1 RLy2 O u t LO t HI t type B U S ADDR PAR DEL BAUD S Y S COnt UPDN DFLT T o T RatI C o n F Back to E X I T dPIn dP_T Back to EN Programming menù diagram IT Schema menù di programmazione ES Esquema menù de pro...