Setting up the Password (
pass
)
The
Password
menu is used for programming three levels of security to prevent unauthorized changes to
the programmed parameter settings.
Pass 1: Allows use of function keys and digital inputs
Pass 2: Allows use of function keys, digital inputs and editing set/reset points
Pass 3: Restricts all programming, function keys, and digital inputs
Total: Prevents resetting the total manually
Gtotal: Prevents resetting the grand total manually.
Protecting or Locking the Meter
Enter the
Password
menu and program a six-digit password.
For instructions on how to program numeric values see
Record the password for future reference. If appropriate, it may be recorded in the space provided.
Model:
Serial Number:
Password 1:
__ __ __ __ __ __
Password 2:
__ __ __ __ __ __
Password 3:
__ __ __ __ __ __
Total
__ __ __ __ __ __
GTotal
__ __ __ __ __ __
Total Reset Password & Non-Resettable Total
The total and the grand total can be password-protected to prevent unauthorized total resets.
The grand total can be programmed as a non-resettable total by entering the password “050873”.
Caution!
Once the Grand Total has been programmed as
“non-resettable” the feature
cannot
be disabled.
!