Helios Large Display Pulse Input Rate/Totalizer Instruction Manual
PD2-6300
48
Display
Parameter
Action/Setting
CutofF
Cutoff
Set low-flow cutoff
Count
Count
Set total and grand total count direction
Tot C
Total Count
Set total to count up or down
Gtot C
Grand Total Count
Set grand total to count up or down
AoutPr
Analog output
programming
Program analog output parameters
Source
Source
Select source for the 4-20 mA output
O-rang
Overrange
Program mA output for display overrange
u-rang
Underrange
Program mA output for display underrange
mAx
Maximum
Program maximum mA output allowed
min
Minimum
Program minimum mA output allowed
Calib
Calibrate
Calibrate 4-20 mA output (internal reference source used for
scaling the output)
4 mA
4 mA output
Enter mA output value read by milliamp meter with at least
0.001 mA resolution
20 mA
20 mA output
Enter mA output value read by milliamp meter with at least
0.001 mA resolution
user
User I/O
Assign function keys and digital I/O
F1
F1 function key
Assign F1 function key
F2
F2 function key
Assign F2 function key
F3
F3 function key
Assign F3 function key
F4
F4 function
Assign F4 function (digital input)
dI I
Digital input 1
Assign digital input 1 – 4, if expansion modules are connected
dO 1
Digital output 1
Assign digital output 1 – 4, if expansion modules are connected
Diag
Diagnostics
Display parameter settings
LED t
LED test
Test all LEDs
Info
Information
Display software and S/N information
Erase
Erase
Delete the MeterView Pro installation files from the meter
Gate Function (
Gate
)
The gate function is used for displaying slow pulse rates. Using the programmable gate, the meter is able
to display pulse rates as slow as 1 pulse every 999.9 seconds (0.001 Hz). The gate function can also be
used to obtain a steady display reading with a fluctuating input signal.
The gate function (
Gate
) is the first option in the Advanced Features menu. There are two settings for the
Gate
, low gate (
Lo G
) and high gate (
Hi G
).