LED Indication
Remote LED for the control panel regime “Status” or red LED of the reader
Goes on for about 5 seconds after the power supply: waits command for con-
figuring by a computer. skips if the panel switches to test mode of the zones.
off: the panel is disarmed.
lit constantly: the panel is arming.
flashes five times per second:
- after power supply of the panel it is not detected voltage from the transformer
(flashes for 30 seconds or until the voltage appears);
- if at arming by a hidden switch, in duration of the exit time: there is an active
instant or delayed zone.
flashes two or three times quickly during a half-second, followed by a half-
second pause: there was an alarm, not in armed mode. this indication disappears
after new arming.
flashes two or three times quickly during a half-second, followed by a half-
second glowing: there was an alarm, the panel is in armed mode. this indication
disappears after new arming.
flashes two or three times quickly during a half-second: there was an alarm,
the panel is in alarm, the siren is turned on.
flashes once per second: passes entry time or exit time.
- level: 5 pcs. green leds „”, „”, „4”, „8” and „6” („” is from the side of the
bridge, „6” is from the side of the siM card); on circuit boards intended for GPrs
communications „” is blue:
- 5 digit binary led indication on the board about the level of GsM radio signal
(csQ): add together glowing leds only, respectively with coefficients , , 4, 8 and
6; by these leds can be determined also the current status of the GsM module:
- led „” is flashing - the microcontroller communicates with the GsM module;
- led „” is flashing - the microcontroller checks the Pin code on the siM
card; if the siM card is not recognized, all 5 leds start flashing; if the siM card is
not unlocked, for about 5 seconds flash simultaneously leds "" and "", then the
module restarts;
- led „4” is flashing - the microcontroller verifies for unerased sMs in the siM
card;
- led „8” is flashing - the GsM module registers in the GsM network;
- led „6” is flashing - the GsM module performed GPrs session and re-
ceives tcP / iP address.