n=08883456 n=08876543 n3=088933 n4=ffffffffff 

n5=FFFFFFFFFF n6=FFFFFFFFFF ln=*102# gm=00

 

- rd3: GPrs parameters:

server iP- "s", server Port- "p", server iP- "s", server Port- "p", encryption 

code ”ec”, Module timeout "mt"[h], server timeout "st”[h], test interval “ti”[h], ac-

knowledge interval “ai”[h], PdP address "pa"

 

sn=ffffff id=037777 gc=007777 s=d5de0 p=65e6 s=d5de0 

p=65e6 ec=00030405060708090a0B0c0d0e0f mt=e st=3c ti=0c ai=3c 

pdp=000000

 

- rd4: GPrs parameters: aPn address "aa", GPrs User name “un”, GPrs 

PassWord “pw”

 

aa=globul@@@@@@ un=username@@@@@ pw=password@@@@

as the symbols @ is displaying of zeros.

 

- rd5: rfid codes – -6

c=0a3B4c,07839f,03acd8e,ffffffff,ffffffff,ffffffff,ffffffff,f

fffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffff

ffff,ffffffff

 

- rd6: rfid codes – 7-3

c=0a3B4c,07839f,03acd8e,ffffffff,ffffffff,ffffffff,ffffffff,f

fffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffffffff,ffff

ffff,ffffffff

 

3. if must be entered a hexadecimal number, compulsory is to be entered two 

characters, even if the first is zero. if the hexadecimal number contains a letter, it 

must be small latin (a, b, c, d, e, f). When entering of  tcP/iP address all the num-

bers must be three-digit even if start with zero. When entering a port, the number 

must be a five-digit, even if it starts with zero.

 

4. When changing the programming code, the new 6 digit code must be en-

tered twice successively delimited by commas:

 

'

cc = 123456,123456, .....

'

 

5. the serial number is not configured via sMs.

 

6. sample texts for configuration via sMs:

code=homeal,za=00,b0,0c,bc,00,00,zd=1a,20,1c,3c,10,10,n1=0877313999,s1=211

,012,013,014,go

code=homeal,s2=211,012,003,014,p1=03567,p2=00123,id=987654,go

code=homeal,aa=internet.vivatel.bg,cc=112233,112233,n2=0877313999,n3=0876

543210,go

code=112233,ec=10,11,12,13,14,15,16,17,18,29,2a,2b,2c,2d,2e,2f,mt=1c,st=2b,am

=0a,xd=3c,go

code=homeal,ar=1a,at=2e,pa=192,168,000,001,z3=Zone3-vrata PIR moment,go

code=homeal,rd0=0877313999.

code=homeal,rd2=0877313999.

code=homeal,bt=3c,ed=1a,20,1c,3c,00,00,ln=*102#,go,rd0=0877313999.

code= homeal,rds=0877313999.

Содержание PC GSM 612

Страница 1: ...PC GSM 612 HOME ALARM GUIDANCE FOR INSTALLERS...

Страница 2: ...the codes 10 c GSM parameters 10 d GPRS parameters 11 e Measured voltage at the terminals of the different kinds of zones 11 6 Inclusion exclusion under arming 11 7 Armed mode 12 8 Announcement 13 9...

Страница 3: ...n to turning on off at arming by telephone permission to send SMS in the failure restore of the AC power GSM number to check the validity and limits of a prepaid SIM card 4 Powerful output 12V 1A for...

Страница 4: ...Warning The events of the twin zones are transmitted to the centre by num bers to which was added 10 for example the twin zone 3 will be displayed as a zone 13...

Страница 5: ...rnal transformer Bt plus and minus of the battery Ld LED Status for indicating of operating mode connects between Ld and Aux 12V with a plus to the Aux Aux 12V power supply for external sensors two lu...

Страница 6: ...chassis minus of the power supply Z5 Zone 5 balanced connects between Z5 and ground HK Zone 6 balanced connects between HK and ground Connecting of the zones is done in the following ways NC unbalanc...

Страница 7: ...tion or fault short circuit for a zone the corresponding LED flashes 5 In the presence of Tamper the indication for active zone goes off 6 In the absence of an active zone the running lights continues...

Страница 8: ...f the zones in a separate scheme 9 Activation time of each of the zones with step 10 ms 10 Permission for arming at active instant or delay zone bypass upon activa tion 11 Method of switching on and o...

Страница 9: ...e 0 Off 1 Delay 2 Instantaneous 3 24 hours 4 Interior 5 Arming hidden switch Active state and balance measured voltages 0 NC unbalanced 0 5V 1 NO unbalanced 4 5V 2 NC balanced 2 9V 3 NO balanced 2 9V...

Страница 10: ...nfiguration code homeal GSM parameters Notification GSM 1 GSM 2 GSM 3 GSM 4 GSM 5 GSM 6 SMS on alarm Yes Dial at alarm No Dial at inclusion exclusion under arming Yes Permission for inclusion exclu si...

Страница 11: ...Alarm Alarm Both Tamper Trouble 0 NC unbalanced 0 5V 5V 1 NO unbalanced 5V 0 5V 2 NC balanced 2 9V 4 5V 0 5V 3 NO balanced 2 9V 0 5V 5V 4 NC bal with tamper 2 9V 4 3V 5V 0 5V 5 NO bal with tamper 4 3...

Страница 12: ...rns off the system generates six squawks and the panel is not included in security 6 The zones status is monitored only at the time of inclusion of the hidden switch If the zone is activated or restor...

Страница 13: ...4 Continuous monitoring of the battery voltage if for 30 minutes in all checking the voltage is 10 5V a message is sent for diluted battery LOW BATTERY TROU BLE ALARM and respectively if for 30 minute...

Страница 14: ...The module sends an SMS to the specified number System ARMED zones A N N A N N AC Power On System disarmed zones N A N N N N AC Power Off wherein A means Active Active zone the zone is activated and N...

Страница 15: ...shes two or three times quickly during a half second there was an alarm the panel is in alarm the siren is turned on Flashes once per second passes entry time or exit time Level 5 pcs green LEDs 1 2 4...

Страница 16: ...rk Flashing 64ms ON 3000 ms off has detected a network Flashing 64ms ON 300 ms off GPRS communication Green LED on the PCB The green LED lights in the presence of AC power Configuring There are two wa...

Страница 17: ...menu they are written in small letters Of each byte in command mode the module returns an echo 8 Alarm Parameters Codes Parameters and GSM Parameters are the three menus for programming 9 After the co...

Страница 18: ...arm Zone 5 Description z5 Zone 5 Alarm Zone 6 Description z6 Zone 6 Alarm Factory Default fd Read RAM Data rd To Main Menu mm 16 The duration of the signal Gong Chime is in 10 ms steps 17 Forced allow...

Страница 19: ...ters not just num bers 23 After entering from the main menu of gp the module sends GSM Parameters APN Address aa internet vivatel bg PDP Address pa 0 0 0 0 Server TCP IP 1 s1 192 168 1 51 Server Port...

Страница 20: ...is very cumbersome it takes more than 30 seconds Better is the announcement by GSM for arisen events to be done via SMS 26 GSM Mode Options these are the options for the operating mode of GSM if GPRS...

Страница 21: ...details the device responds with OK For example Serial Number serial number of the module 6 digits sn 77 77 77 the answer is 40 Command for reading rd After its submission the display shows RAM Data...

Страница 22: ...ement of individu al commands does not matter important is just to begin with code and the correct configuration code and ends with go If at the end there is a number to which the module to send an SM...

Страница 23: ...3 If must be entered a hexadecimal number compulsory is to be entered two characters even if the first is zero If the hexadecimal number contains a letter it must be small Latin a b c d e f When enter...

Страница 24: ...ve state and for balance of the sensors see the figure Variants of connecting zones normally open or closed contact balanced or unbalanced with tamper or without tamper paired or single by default all...

Страница 25: ...phone 10 Arm and disarm by configured method The LED Status should be lit at arming and go off on disarming 11 If at the time of arming with a secret switch there is an active zone disarm ing is not...

Отзывы: