9
Configuration tables
Parameters for the zones
Parameter
Zone Zone Zone 3 Zone 4 Zone 5 Zone 6
entry delay [sec]
5
0
0
0
0
0
Zone type
5
active state and balance
Bypass upon activation
-
-
-
-
-
-
activation time [x0ms]
30
30
30
30
30
30
Gong in the siren
yes
-
-
-
-
-
exit delay [sec]
40
duration of the gong [x0ms]
0
activity of the siren [sec]
60
delay in the indication of a power
failure [min]
30
delay in the indication for restora-
tion of the power [min]
5
Zone type: 0 = off, = delay, = instantaneous, 3 = 4 hours,
4 = interior, 5 = arming (hidden switch).
active state and balance (measured voltages):
0. nc, unbalanced
<0,5V . no, unbalanced
> 4,5V
. nc, balanced
,9V 3. no, balanced
,9V
4. nc, balanced, with tamper
,9V 5. no, balanced, with tamper
4,3V
6. nc, paired zones, with tamper ,8V 7. no, paired zones, with tamper 4,3V
8. nc+ no, paired zones, with tamper ,9V
nc = normally closed contact; no = normally open contact.
the tamper is always nc.
Balancing: with a resistor 5k6 of the line (see diagram "Variants of connecting
zones).
description of the zones (numbers and latin characters) - maximum of 3
characters:
Zone : ...............................................................................................................
Zone alarm
Zone : ...............................................................................................................
Zone alarm
Zone 3: ...............................................................................................................
Zone 3 alarm