[E-08]-[CH1]
Temperature
probe 1 is above
the upper limit
Short running time
controller parameter setting is not
reasonable
Wait for a while
Check the controller parameters and
reset the unreasonable parameters.
Please refer to the common parameter
settings of the controller.
[E-08]-[CH2]
Temperature
probe 2 is above
the upper limit
Short running time
controller parameter setting is not
reasonable
Wait for a while
Check the controller parameters and
reset the unreasonable parameters.
Please refer to the common parameter
settings of the controller.
[E-10]-[CH1]
Temperature
probe 1 is
connected
inversely
Outlet temperature probe is
connected inversely
Interchanging temperature probe wire
[E-10]-[CH2]
Temperature
probe 2 is
connected
inversely
Inlet temperature probe
connected inversely
Interchanging temperature probe wire
[E-12]-[ PWR]
Heating energy
shortage
Heater failure
Contactor fault
Replace heater
Replace Contactor
[E-13]-[MLOW]
Water shortage
Booster pump failure
Liquid level detection switch failure
Replace booster pump
Replace the liquid level detection switch
[E-15]-[ ATF ]
PID calibration
fault
Heater failure
Contactor fault
Temperature probe failure
Replace heater
Replace Contactor
Replace the temperature probe
18