F08
Upper limit of temp.
setting
Upper limit of temp. setting
(
The parameter of
FOH series is280.
)
120
0-350
32-662
℃
/
℉
F09
Time of insufficient
heating
After switch on, machine cannot reach the
setting temp after heater runs a while and then
alarm.
3600
0-9999
sec
F10
Interval time of
Interval exhaust
Exhaust as every setting time.
0
0-9999
sec
F11
Running time of
Interval exhaust
Running time of interval exhaust
0
0-9999
sec
F12
Unit of temp.
Celsius or Fahrenheit temp.
0
0
:
℃
1
:
℉
F13
Low water level
checking time
(It’s useless for FOH
series.)
If the signal of low water level is kept about
the setting time, the signal is confirmed.
5
0~60
sec
F14
Time of pressure
relief
When refilling water, pressure relief and
exhaust are opened at the same time and
kept based on the setting time.
0.0
0~9.9
sec
F15
Time of refilling water
(It’s useless for FOH
series.)
After confirming the signal of low water level,
machine will refill water. If the signal isn’t
disappeared after refilling water and then
alarm [E-13]-[MLOW] (Refilling water is
insufficient.)
120
0~300
sec
F16
Blowing time
(It’s pump reversal for
FOH series.)
If customer doesn’t close blow manually, the
blow function will be closed automatically as
reaching the setting time.
30
0-9999
sec
F17
3 phase checking
Whether customer checks 3 phase power or
not?
OFF
OFF: close
ON: open
F18
PV value shows
decimal point
Show decimal point or not.
OFF
ON:PV shows
decimal point
OFF:PV
doesn’t show
decimal point
F19
OFS1 CH1
Temp. Correction
Correct wire deviation V.S. deviation of actual
temp signal.
0.0
-
99.9~100.0
℃
/
℉
F20
GAI1 CH1
Magnification
Correction
Adjust the error value of wire to correct
magnification value.
1000
1~1500
F21
OFS2 CH2
Temp. Correction
Correct wire deviation V.S. deviation of actual
temp signal.
0.0
-
99.9~100.0
℃
/
℉
15