3.7 BASIC OPERATION
1. Turn on the main power switch
shows [OFF]; waiting operation;
2. Switch on
(
1
)
Press
, blower start to operate, heater delayed operation.
(
2
)
show current temp.
,
show current parameters.
3. Pump on and off
(
1
)
Pump on: after power supply, pump is operated delay. Pump starts operating after reaching
time. Set by parameters 3: [F-03]
(
2
)
Pump off: press
when pump operation, pump is delay off and then pump is off after
reaching time or temp. (Delay off - parameters 3: [F-06], Delay time or temp. -
parameters 3:[F-05])
4. Heater on and off
(
1
)
Heater on: after pump is operated, heater starts delay timer. It starts after reaching time.
(Delay time - c 3:[F-04])
(
2
)
Heater on: heater is delay on. (Delay time - parameters 3: [F-05])
(
3
)
Heater off: press
when heater on and then heater is closed forcedly. Meantime, cooling
is on.
5. Switch off
Press
when running,
shows[OFF] and current temp. interactively and then heater is
closed and pump is delay off. After pump stops working, machine will be turned off and shows
[OFF].
6. Pre-start machine
(1) When switch off, press
,
shows [OFF] and
shows (countdown time).
Machine is switched on and run timely. Please see the function code [F-71].
(2) During the timing, press
, the timer will be closed and then
shows [OFF].
7. Blow ON/OFF
(1) Blow on: during stop working, press
and then blow on.
11