Install in reverse order. 

 

 

 

4.4 HEATER 

1) Open  the heating cover (as shown in the picture, first press the black switch downward 

and then open the heating cover outwards) 

    

              

 

2) Remove the heating tube cover (as shown in the figure, unscrew the screws, loosen the 

wire clamp and remove the heating tube cover). 

 

               

 

           

3

After cleaning  the electric heat pipes,  installs  the electric heat pipes back into the 

machine in reverse order

 

Solenoid valve

 

 

24 

Содержание MFT1230C

Страница 1: ...t confuse these with any other make model or manufacturer LASTIC ROCESS QUIPMENT INC www ppe com e mail sales ppe com E 8303 CORPORATE PARK DRIVE A MACEDONIA OHIO 44056 2300 S 216 367 7000 FAX 216 367...

Страница 2: ...L A M P 1 0 3 6 S E T T I N G B U T T O N 1 0 3 7 B A S I C O P E R A T I O N 1 1 3 8 T E M P E R A T U R E S E T T I N G A N D A U T O T U N N I N G 1 2 3 9 T E M P E R A T U R E L I M I T A N D T I...

Страница 3: ...1 WATER QUALITY STANDARD Please note the water quality for supplying water to molding temperature controllers or other related machines If the water quality is bad the rust in pipes results in water f...

Страница 4: ...r cloth which might result in dangerous situation When power outage please turn off power supply In order to prevent accident from power problem when static electricity please switch off MTC Please we...

Страница 5: ...223 8305 PPE 1 4 WARNINGS AND CAUTIONS LABEL INTRODUCTION Attention Please maintain the machine as the maintenance schedule Attention Please read the manual before starting the machine The maximum tem...

Страница 6: ...his process if the temperature of high temperature water is too high the system will start the solenoid valve and the cooling water will enter the system for direct cooling so as to reduce the tempera...

Страница 7: ...intenance do not sit on the machine or put things Do not rotate flammable and explosive materials around the machine 2 2 PIPING INSTATLLATIONS 1 Connect the machine to the mold with Teflon hose and us...

Страница 8: ...200 C Teflon pipe with temperature resistance of 200 C can be used When the operating temperature of the machine is 200 C 300 C the Teflon pipe with temperature resistance of 300 C must be used 2 3 PO...

Страница 9: ...0 0 2 SV Parameters Temp And parameters Set Values 3 3 DESCRIPTION OF KEY PAD ITEM Name Explanation Remarks 3 Switch ON OFF Switch on TEMP shows OFF After switch on pump and heater delayed operation S...

Страница 10: ...ooling 3 5 DESCRIPTION OF ALARM LAMP ITEM Name Explanation Remarks 11 Pump Overload Lighten as pump overload 12 Water Shortage Lighten as water shortage 13 Over Heat Lighten as over heat When temp is...

Страница 11: ...time or temp parameters 3 F 05 4 Heater on and off 1 Heater on after pump is operated heater starts delay timer It starts after reaching time Delay time c 3 F 04 2 Heater on heater is delay on Delay...

Страница 12: ...it will display temp CH3 If customer would like to check the temp of control box please press it will show the temp 3 8 TEMPERATURE SETTING AND AUTO TUNNING 1 During running shows the current temp 2...

Страница 13: ...shows CH1 temp 2 Press 2 sec at the same time enter parameters 2 shows F01 1 which is upper limit alarm code of CH1 temp 3 Press or to increase or decrease the value 4 Press to save the current value...

Страница 14: ...Molding Actual temp Setting temp Temp upper limit PV SV F01 3 alarm and shows E 08 CH3 15 0 250 F02 2 Lowest limit of CH2 temp Inlet Actual temp Setting temp Temp lowest limit PV SV F02 2 alarm and sh...

Страница 15: ...ened at the same time and kept based on the setting time 0 0 0 9 9 sec F15 Time of refilling water It s useless for FOH series After confirming the signal of low water level machine will refill water...

Страница 16: ...1 2 F83 Setting password Set the password by entering LK 1 3 0 9999 Enter the password in F 81 F22 GAI2 CH2 Magnification Correction Adjust the error value of wire to correct magnification value 1000...

Страница 17: ...e power supply Check three phase power supply Replace the circuit board E 03 OVL Pump overload Pump failure Thermal relay FR current setting error Replace the pump The correct setting of the thermal r...

Страница 18: ...d reset the unreasonable parameters Please refer to the common parameter settings of the controller E 10 CH1 Temperature probe 1 is connected inversely Outlet temperature probe is connected inversely...

Страница 19: ...e mail sales ppe com W 6385 MONTESSOURI STREET LAS VEGAS NEVADA 89113 1186 TOLL FREE 800 258 8877 Order Fax 800 223 8305 PPE 3 12 COMPLETE FUNCTION 19...

Страница 20: ...ted effective range Prevent over adjustment from integral action 100 0 100 F 32 No induction Set no induction band of heating and cooling If there is only heating function it should be on induction ba...

Страница 21: ...d Set the password by entering LK 1 3 0 9999 Enter the password in F 81 F 84 Lock layer Choose the parameter layer to lock 0 0 F Table 1 2 Universal password 9898 F 85 Setting password Set the passwor...

Страница 22: ...emp cutting power supply drainage oil and water first 2 Please ensure the machine stops working before maintenance and check because high temp and then wearing the glove also 3 In order to extend the...

Страница 23: ...the Y filter in the water inlet to avoid the impurities get into the pipes 2 When the impurities flow into the machine it may cause the malfunction of the machine or the decrease of the temperature c...

Страница 24: ...ating cover as shown in the picture first press the black switch downward and then open the heating cover outwards 2 Remove the heating tube cover as shown in the figure unscrew the screws loosen the...

Страница 25: ...e mail sales ppe com W 6385 MONTESSOURI STREET LAS VEGAS NEVADA 89113 1186 TOLL FREE 800 258 8877 Order Fax 800 223 8305 PPE 5 CIRCUIT DIAGRAM 1 Electrical layout 230V 25...

Страница 26: ...e mail sales ppe com W 6385 MONTESSOURI STREET LAS VEGAS NEVADA 89113 1186 TOLL FREE 800 258 8877 Order Fax 800 223 8305 PPE 2 Circuit diagram 230V 26...

Страница 27: ...e mail sales ppe com W 6385 MONTESSOURI STREET LAS VEGAS NEVADA 89113 1186 TOLL FREE 800 258 8877 Order Fax 800 223 8305 PPE 27...

Страница 28: ...FU 10 1A 2 KM1 Contactor SC E02PM C AC 220V 50HZ 1 KM2 Contactor SC E2SPM C AC 220V 50HZ 60HZ 1 FR Thermal overload relay TK E02 C 2 8 4 2 A 1 MX Release AC DC 110V 400V 1 TB Terminal TB2506 600V 25A...

Страница 29: ...ter Housing 1 5 MFT0005 SUS304 1 2 1 2 3 4 T Tube 1 6 MFT0006 SUS304 3 8 T Tube Inner Teeth 1 7 MFT0007 YS 20A 120 Pump 230V 1 7 MFT0008 YS 20A 120 Pump 460V 1 8 MFT0009 Front Caster 2 8 MFT0010 Rear...

Страница 30: ...MFT0021 Circuit board holder 1 2 MFT0022 Circuit board 1 3 MFT0023 Control box 1 4 MFT0024 buzzer 3 24V DC 1 5 MFT0025 RS485 interface PCB board 1 6 MFT0026 RS485 holder 1 7 MFT0027 Cable fixing head...

Страница 31: ...t breaker specifications 1 ______ A 3 _____ A 7 3 CHECK DAILY Check the machine switch function Check all the cables of the machine 7 4 CHECK WEEKLY Check electrical components for loose joints Check...

Отзывы: