background image

 

18 

audible, depending on ambient noise level.)  

NOTE:

 To reduce splash-out, the 

spray pumps will be stopped while the stencil is lowering. 

9.

 

When the ultrasonic cycle ends, the stencil will automatically rise from the tank 
and stop part way from the top to help wash the bottom of the stencil where 
residues may accumulate.  The distance the stencil rises is controlled by the     
[

Up Transit

] setting on the “Timer Setup” screen. 

10.

 

 After a time, the stencil will continue its rise to the top.  The wait period is 
controlled by the [

Dwell

] setting on the “Timer Setup” screen. 

11.

 

 If it is necessary to end a cleaning cycle before the time is completed, depress 
the [

AUTO CYCLE

] button to cause the Automatic Cycle to be [

DISABLED

].  

Depress both yellow buttons simultaneously to raise the item from the tank.  
Continue holding the yellow buttons until the [

TOP

] indicator lights, and then 

release the buttons.  If desired, the [

AUTO CYCLE

] button may then be 

depressed to return to the system to [

ENABLED

], allowing additional automatic 

cleaning cycles. 

12.

 

 NOTE

:  If, at any time, the fluid level in the front tank drops below the 

operating point, the [

FLUID LEVEL

] indicator at the top of the Operations 

Screen will flash the word [

ADD

].  The pumps and ultrasonic generator are 

locked out under this condition.  The user must then add sufficient fluid (at the 
proper dilution) to bring the level in the front tank to within three inches of the 
top of the tank.  When this is completed, depress the [

FLUID LEVEL

] indicator 

to restore operation.  The indicator will then indicate [

OK

] until the next such 

occurrence.  

NOTE:

 If an automatic cleaning cycle is in progress, it will be 

aborted and the arm will rise.  A new automatic cycle may be initiated after the 
fluid is replenished. 

 
 

III.5  Dryer Cycle 

 
Open the drying chamber at the rear of the machine.  Unlock the stencil and lower it 
into the dryer.  Close the cover and press the DRYER [

START

] button on the 

Operations screen.  The button will turn from green to yellow and display the word 
[

RUNNING

] to indicate that the dryer is on.  To turn the dryer off before the cycle 

is complete, push the DRYER [

STOP

] button.  Any subsequent dry cycle will run 

for the full time set.  The dryer is equipped with a manual-reset high temperature 
cutoff device.  It opens at 160 F. 
 
The Blue readout below the DRYER [

STOP

] button will show the number of 

seconds remaining in the drying cycle.  When the dryer is not running, it displays 
the programmed length of the dryer cycle. 
 
During the drying cycle, additional stencils may be cleaned by following steps 1 
through 8 while the dryer is running.  Drying will be expedited if excess fluid is 

Содержание PPC-N29TP

Страница 1: ...NIC STENCIL CLEANING SYSTEM Operator s Manual Rev 3 September 2008 PresSure Products Company Inc 4540 Washington Street West Charleston WV 25313 2010 800 624 9043 304 744 7871 Fax 304 744 6705 www pre...

Страница 2: ...200 25 Premix 9 Measuring Solution Concentration 9 III 3 Starting the Machine 10 Machine Security Code 14 Timer Setup Procedure 15 III 4 Running an Automatic Cycle 16 III 5 Dryer Cycle 17 III 6 Manual...

Страница 3: ...Schematic Diagram 4 2 Operator Control Panel 6 3 Safety Disconnect Switch 7 4 Operations Screen 10 5 Fluid Temperature Screen 13 6 Timer Setup Screen 15 7 Operations Screen 16 8 Manual Functions Scre...

Страница 4: ...stencils for silkscreen printing in the electronics industry where adhesive or solder cream is used The machine may also be used to clean tools or circuit boards without components Certain boards with...

Страница 5: ...e PPC N29TP has two filtration systems The fluid from the larger tank may contain particles of adhesive or heavy residues soldering cream alloys The alloy particles will fall out in a gravity pre filt...

Страница 6: ...consists of a powerful cross flow fan and a resistance heating element The dryer which has an adjustable timer is activated by control buttons on the touch screen panel The dryer is equipped with a ma...

Страница 7: ...tton should be pushed only in an emergency when it is necessary to deenergize the entire machine When pushed it removes power from the Programmable Logic Controller PLC Removal of PLC power will cause...

Страница 8: ...ion III 1 Recommended Cleaning Fluid Zestron Corporation s Vigon SC200 stencil cleaning product is recommended for use in the PPC N29TP This product has the advantage of entering the microphase above...

Страница 9: ...on the long housing under the top housing Seat the filter on the boss in the top housing raise the filter housing rotate to the right to thread it into the top housing and tighten securely hand tight...

Страница 10: ...ventually seat itself on the boss in the lower housing Repeat for the other long filter Open the tank valves V1 and V2 fully Again using the siphon pump dispense the stirred SC200 premix into the rear...

Страница 11: ...ppear FIG 4 OPERATIONS SCREEN This screen shows the machine s operational status at a glance and contains all necessary controls to run automatic cleaning cycles The TEMP F indicator reports the measu...

Страница 12: ...If it is displays CHANGE the filter cartridge should be replaced This condition does not prevent operation The state of this indicator is controlled by pressure switch PS1 The indicator will not be v...

Страница 13: ...in the Shutdown Mode Check the SHUTDWN TMR indicator If it says PUMPS STOPPED briefly touch both yellow buttons to turn the pumps on again The SHUTDWN TMR indicator will then indicate RUN The DRYER ST...

Страница 14: ...re is outside of preset limits To set the minimum fluid temperature level take the following steps 1 Touch the SET TEMP button on the screen 2 Enter the desired temperature in whole numbers e g 78 Thi...

Страница 15: ...ems being cleaned This parameter is set using the ABORT TEMP button Enter the maximum allowable temperature in the same manner as for the SET TEMP button If the fluid temperature reaches the maximum p...

Страница 16: ...the proper setting may need to be determined by running a few cycles This timer determines the position where the arm will pause on its way back to the top position 6 The Dwell timer is also set in th...

Страница 17: ...the word READY must be displayed on the status indicator below it If it still says NOT READY check the FLUID LEVEL indicator to make sure it is displaying OK If it displays ADD fluid must be added to...

Страница 18: ...mps and ultrasonic generator are locked out under this condition The user must then add sufficient fluid at the proper dilution to bring the level in the front tank to within three inches of the top o...

Страница 19: ...essary to reverse the direction of travel for the lift arm For these reasons a password protected Manual Functions screen is provided and can be accessed from the Operations screen Simply press the bu...

Страница 20: ...n at about 115 F until the ultrasonic generator is returned to AUTO and the fluid is allowed to cool Do not leave the ultrasonics operating while unattended for extended periods this can lead to erosi...

Страница 21: ...urn off On the Operations screen the SHUTDWN TMR indicator will turn red and read PUMPS STOPPED indicating that the shutdown is in effect The filter indicators will be hidden To run another cleaning c...

Страница 22: ...RSET Filter Change Procedure Remove the front compartment panel by turning the two black fasteners turn counterclockwise Tilt the panel out from the top then lift up to remove it NOTE The three O ring...

Страница 23: ...d tight 6 Repeat for the other long housing 7 Unscrew the smaller filter housing and empty the fluid Use the supplied filter wrench if necessary 8 Thoroughly clean the bowl and scrape out any residue...

Страница 24: ...ly close valve V2 at the bottom rear of the compartment to restrict the flow and simulate filter loading At the exact point when visible reduction in flow is noted stop 9 Turn the thumbwheel on pressu...

Страница 25: ...ates the risk of running the pumps dry which might damage them This mode should be used only when draining the machine and only by trained personnel 4 Return to the Operations Screen by pressing the b...

Страница 26: ...ons Power supply 220 240 volt 1 phase 50 60 Hz Current 20 amperes max Electrical Plug NEMA Type 6 20P 250 V 20 A Mating Recept NEMA Type 6 20R 250 V 20 A Filters Spun Polypropylene 5 micron 20 Size 2...

Страница 27: ...27 MACHINE SECURITY CODE When the Security Code screen appears depress 1 2 3 and ENTER Remove this page from manual to safeguard code if desired...