14
4. Three other screens are provided for machine setup. The access to these screens
is password protected. To access them, press the
[+]
key in the lower right corner of
the Operations screen. The Security Code screen will appear. Enter the proper
passcode and the following “Fluid Temperature” screen will then appear:
F
IG
.
5:
F
LUID
T
EMPERATURE
S
CREEN
This screen indicates the temperature of the cleaning fluid, and allows setting of the
desired temperatures. It also shows alarm indicators if the temperature is outside of
preset limits.
To set the minimum fluid temperature level, take the following steps:
1.
Touch the [
SET TEMP
] button on the screen.
2.
Enter the desired temperature in whole numbers (e.g., 78). This can be any
number between 70 and 100; press [
ENTER
].
3.
The [
SET TEMP
] button should reappear, displaying the set value.
Status Indicators
HIGH
– Temperature is greater than 115
o
F.
OK
– Temperature is above the setpoint, but less than 115
o
F.
LOW
– Temperature is below the setpoint. The fluid heaters will operate.
HEAT ON
– Power applied to electric fluid heaters.
NOTE:
The pumps must be running and the [
MAIN FILTER
] indicator must be
indicating [
OK
] for the heaters to function. The fluid heater is equipped with a