background image

Generator Parts List – 74006 Rev A.3  

60 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

        

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ref  

Part # 

Description 

Qty 

57 

 Kit # 7 

Right leg 

58 

 Kit # 8 

Pin clip 

59 

  Kit # 8 

Flat washer M18 

60 

800310 

Or Kit # 8 

Wheel 

61 

Kit # 8  

Wheel axle shaft 

62 

800311 

Right side cover 

63 

800312 

Seal ring 

64 

800313 

Lever connecting bracket 

65 

800527 

Seal ring 

66 

800315 

Lever connecting bracket 

67 

800316 

Seal ring 

68 

Kit # 5 

Cushioning rubber 

69 

800528 

Components of frame 

70 

800318 

Frame girder 

71 

800319 

Seal ring 

72 

800320 

Cushioning rubber 

74 

  Kit # 10 

Canister bracket 

75 

  

 Kit # 9  

  

Muffler guard shield 

76 

Bolt with flange M8x12 

77 

Cushioning rubber 

78 

Bolt with flange M6X8 

79 

800322 

Oil drain release plug 

80 

Kit # 10 

Canister pipe 

81 

Carbon canister assembly 

82 

Canister hose  

83 

800323 

Bottom frame plate 

84 

800324 

Left side cover 

85 

800325 

Tank front cover 

86 

  

  
  

 Kit # 11 

  

  
  

Nut with flange M10 

87 

Engine support plate 

88 

Engine support plate 

89 

Nut with flange M8 

90 

Engine iso mount 

91 

Engine iso mount 

92 

Engine iso mount 

93 

800326 

Muffler reinforcement plate 

94 

 790978 

Bolt with flange M6X14 

95 

800327 

Heat insulation (glass fiber

 

96 

800328 

Muffler heat insulating plate 

97 

Kit # 12 

Bushing 

98 

Muffler 

99 

  Kit # 12, 13, 29  Muffler gasket 

100 

 Kit # 13   

Exhaust outlet pipe 

101 

Kit # 13, 29 

Outlet gasket 

102 

Kit # 13 

All metal hexagon locknut M8 

103 

Bolt M10X40 

104 

800329 

Tank back cover 

105 

Kit # 17  

Bolt with flange M6X30 

106 

800330  

Or Kit # 17  

Cover plate sealing ring 

107 

800331 

Or Kit # 17 

Fuel level sensor cover plate 

108 

Kit # 14 

Fuel cap  

109 

Fuel strainer 

110 

800332 

Fuel tank seal ring 

111 

800333 

Or Kit # 17  

Philips head screw M5X16 

112 

800334 

Or Kit # 17 

Fuel level sensor 

113 

 Kit # 17 

Connecting plate 

114 

Spacer 

115 

Rubber grommet  

Ref  

Part # 

Description 

Qty 

  

 Kit # 16 

  

Bolt with flange M8x26 

Flat washer M12 

Washer M12 

Kit # 1 

Slotted pan head screw M5X10 

Battery maintenance cover 

Kit # 2 

Cross pan head screw M4X18 

Fuel switch knob 

Kit # 3, 4, 6    Cross small pan head screw M5X12 

38 

Kit # 3 

Components of control panel 

10 

800290 

 Or Kit # 3 

Multifunctional meter 

11 

800291 

Or Kit # 3 

Start control module 

12 

800292 

Or Kit # 3 

Nut with flange M4 

13 

800293 

Bolt with flange M6 X 15 

14 

800294 

Front plastic panel  

15 

800295 

Cable connection panel 

16 

 Kit # 1 

Clip nut M5 

17 

800296 

Cap nut M6 

18 

800297 

Fuse box combination 

19 

 Kit # 4 

Combination switch 

20 

800298 

Or Kit # 4 

Fuel valve  

21 

800299 

Or Kit # 4 

Bolt with flange M6X10 

22 

  Kit # 4, 10  Clip combination 

23 

Kit # 4 

Oil tube 

24 

Kit # 4, 10 

Hose clamp  

25 

Kit # 4 

Fuel line 

26 

Fuel filter 

27 

Fuel line 

28 

800300 

Front inverter shroud 

29 

  
  

 Kit # 5  

  

  

Bolt with flange M6X28 

30 

Flat washer M6 

31 

Cushioning rubber 

32 

Bushing 

33 

Inverter assembly 

34 

800301 

Bolt with flange M6X20 

35 

800302 

Nut with flange M6 

12 

36 

800303 

inverter mounting bracket 

37 

  

Kit # 6  

  

Battery bracket 

38 

Bolt with flange M6X25 

39 

Battery cushion 

40 

  

  
  

Kit # 16  

  

  
  

  

Socket head screw M8X25 

41 

Socket head screw M8X45 

42 

Handlebar connecting seat - left 

43 

Lever rubber grip 

44 

Lever location block 

45 

Locking handle 

46 

Tension spring 

47 

Handlebar connecting seat - right 

48 

800304 

Or Kit # 16 

Rubber handle grip individual 

49 

800305 

Or Kit # 6 

Battery strap 

50 

800306 

Back inverter shroud 

51 

800307 

Seal ring 

52 

790980 

Bolt with flange M6X16 

53 

800308 

Recoil air shroud 

54 

800309 

Wire tie 

55 

 Kit # 7 

Left leg 

56 

 Kit # 7, 8  

Bolt with flange M8X16 

Содержание 74006

Страница 1: ...ted outdoor rated grounded extension cords of proper size NEVER plug the generator directly into a wall outlet ANY connection to a building s electrical system MUST ISOLATE THE GENERATOR FROM UTILITY...

Страница 2: ...esult in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous si...

Страница 3: ...a Suitable Site 27 6 Grounding the Generator 29 Operation 1 General Safety Rules for Operation 30 2 Preparing for Operation 33 3 Starting the Generator 38 4 Checking Generator Output 39 5 Connecting...

Страница 4: ...d grounding requirements for running this generator More detailed information can be found in the Installation Initial Set up steps 5 and 6 of this manual Contact Powerhorse Product Support at 1 866 4...

Страница 5: ...and private owners who loan this equipment to others All persons to whom you rent loan this generator must have access to and read this manual Keep this owner s manual with the generator at all times...

Страница 6: ...gher Oil Capacity 1 53 US quarts 1 45L Noise Level dB 7 meters 55 at 1 4 load 63 9 at rated load Starting Method Recoil Electric Start Spark Plug BPR6ES BP6ES NGK or F7RTC F7TC Torch Battery Specs 12...

Страница 7: ...nsafe operation could result To order replacement safety labels call Powerhorse Product Support at 1 866 443 2576 Ref Part Description Qty 1 790858 Overfill Spark Decal 1 2 790856 Improper Connection...

Страница 8: ...Safety Label Locations 8 2 4 5 1 6 6 7 6 3 8...

Страница 9: ...ption Ref Description 1 Fuel Tank Cap 8 Muffler 2 Control Panel 9 Carbon Canister 3 Handles 10 Air Cleaner 4 Battery Location 11 Carburetor 5 Inverter Location 12 Left Side Cover 6 Right Side Cover 13...

Страница 10: ...ides a means for lifting the generator Reference 8 Muffler An acoustic device installed onto the exhaust system that is designed to reduce noise The outlet includes a spark arrester Reference 9 Carbon...

Страница 11: ...l Operation Outlets 15 120V 30 Amp Locking Receptacle NEMA L5 30R 8 120V 240V 50 Amp Receptacle NEMA 14 50R Control Panel Function There are different kinds of electrical features on the generator con...

Страница 12: ...he ESC Throttle switch must be turned to MAX when using electrical devices that require a large starting current like a submersible pump or air compressor USB Outlet The USB outlet allows for a connec...

Страница 13: ...ts Outlets for connecting a special parallel cable not included for parallel running of two generators Parallel cable kit item 157247 is available to purchase from Northern Tool Equipment Voltage Sele...

Страница 14: ...reen shows the operating status of the generator Pushing the operation key M will toggle through the status of the generator including voltage amperage power frequency rpm run time cumulative time rem...

Страница 15: ...Machine Component Identification 15 Liquid Crystal Display LCD Screen 21 Battery Voltage greater than 12V 25 Battery More than 8V and less than 12V...

Страница 16: ...tage occurs when the AC voltage is greater than 133V and DC voltage is greater than 275V for more than 1 second Under voltage occurs when the AC voltage is less than 108V and DC voltage is less than 3...

Страница 17: ...ation to protect the generator and any connected electric devices The output indicator light green will go off and the overload fault indicator light red will stay on but the engine does not stop runn...

Страница 18: ...er than the running wattage The running and starting wattage requirements are often listed on a device s nameplate If wattage is not given on the device s nameplate the wattage may be calculated by mu...

Страница 19: ...kjet Printer 80 Iron 1200 Laser Printer 950 Lights ten 75 Watt light bulbs 750 Microwave Oven 1000W 1000 Milk Cooler 1100 1800 Milker Vacuum Pump 2 HP 1000 2300 Miter Saw 10 1650 2400 Oscillating Fan...

Страница 20: ...Microwave Oven 1000W 1000 W Air Conditioner Window 10 000 BTU 2200 W Sump Pump 1 3 hp 1300 W Total 6750W In this example the generator must have a continuous output of at least 6750 watts to power al...

Страница 21: ...r source 5 Selecting a site for using the generator 6 Grounding Each of these steps is discussed in detail below 1 Unpacking Delivery Inspection You should inspect the generator immediately after it s...

Страница 22: ...ator which would not be covered under warranty 1 Lift front of generator to install the left leg and the right leg 6 with two bolts each 5 Torque 11 16 Ft Lbs 15 22 N M Note There is a leg for the lef...

Страница 23: ...our hand or any non insulated tools If battery acid contacts skin or clothing flush immediately with water and neutralize with baking soda Accessing the battery 1 Remove the screw 1 and then remove th...

Страница 24: ...ce for a Building Contact a licensed electrician to install an UL listed transfer switch if you want to use your generator as a back up power source for a building What does a transfer switch do It a...

Страница 25: ...2 120 Volt 30 Amp locking receptacle NEMA L5 30R receptacle compatible with NEMA L5 30P mating plug 3 120 240 Volt 30 Amp locking receptacle NEMA L14 30R receptacle compatible with NEMA L14 30P matin...

Страница 26: ...frayed or otherwise damaged WARNING Use of damaged electric cords can cause electric shock or fire Note If an extension cord becomes hot to the touch it is overloaded or damaged and must be replaced N...

Страница 27: ...elow for choosing a location to operate your generator in order to avoid carbon monoxide poisoning The location you choose to operate the generator must be OUTDOORS and away from all air intakes Never...

Страница 28: ...e that all parts of canopy are at least 7 feet from exhaust and allow for adequate clearance above generator so that heat does not build up Hot Exhaust Clearance The exhaust gas from your generator is...

Страница 29: ...e 3 Run a 10 gauge or 8 gauge wire from the clamp to the generator grounding post located on the electrical panel 4 Do not connect the generator grounding post to a water pipe or a ground used by a ra...

Страница 30: ...and operation Only trained adults should set up and operate the generator Do not let children operate Intended use Carefully read about and understand the intended use of this generator Do not use fo...

Страница 31: ...rate the generator or handle any electrical equipment while standing in water while barefoot while hands are wet or while in the rain or snow Electric shock may result Ground fault circuit interrupter...

Страница 32: ...ain static electric charge as can objects made of conductive material e g metal water if they are not electrically grounded The static electric charge on an object such as a human body or plastic fuel...

Страница 33: ...gases EVEN if you run a fan or open windows Carbon monoxide exhaust is given off whether you are using gasoline natural gas or propane to power the generator Ground Generator Make sure the generator i...

Страница 34: ...add oil before first use IMPORTANT Under long continuous run operating conditions be prepared to Check engine oil level every time you refuel the generator Change oil after the first 20 operating hour...

Страница 35: ...ild up in the generator s tank Always use a portable container to fill the tank See warning box regarding static electric spark hazards below b Fill gasoline tank OUTDOORS never indoors c Stay away fr...

Страница 36: ...ed because it dissipates charge to ground more readily 5 Clean up gasoline spills splashes immediately If possible move the generator away from spilled gasoline on the ground Wipe up spilled gasoline...

Страница 37: ...ice you will be powering with the generator 120V or 240V 2 Before starting the generator use the voltage selector switch to switch between 120V ONLY and 120V 240V 120V ONLY gives full 6500 watts of po...

Страница 38: ...ched on b Fuel is switched on c Choke is switched on NOTICE The engine choke is controlled electronically to start the engine 3 Electric Start Push and release the engine switch on the control panel t...

Страница 39: ...oads to the generator Output voltage should be checked with a portable voltage meter 1 Start engine and allow to warm up for five minutes Do not connect any loads 2 Use voltage meter to check output v...

Страница 40: ...ions 1 Allow engine to reach operating speed by allowing it to warm up for approximately 5 minutes before connecting electrical devices 2 After engine is warmed up begin by connecting the items that r...

Страница 41: ...l Set up section Ensure that the ESC throttle switch is in the MAX position on both generators Ensure that the voltage selector switch is in the 120V 240V position on both generators Make sure all dev...

Страница 42: ...anel is green 2 Start the second generator and make sure that the output indicator light on the control panel of the second generator is green Connecting Appliances 1 Plug an appliance into the approp...

Страница 43: ...location or by untrained persons Exercise Generator every 4 weeks The generator should be exercised regularly At least every four weeks start the engine and let it run for 10 to 15 minutes with a smal...

Страница 44: ...plug 10 Add one teaspoon oil through spark plug hole 11 Place rag over spark plug hole and turn starter or pull the recoil a few times to lubricate the combustion chamber 12 Replace spark plug but do...

Страница 45: ...remove spark plug s or spark plug wire s before working on the engine or generator to prevent accidental starting Replace guards Make sure all guards and shields are replaced after servicing the gene...

Страница 46: ...d amount and type of engine oil then install and tighten the oil filler cap 1 See Specification section for oil type and capacity NOTICE DO NOT tilt generator when adding engine oil This could result...

Страница 47: ...ment a Place the generator on a level surface b Open left side cover by turning screw turn c Remove the air filter housing cover paper filter and foam element d Replace paper filter with a new filter...

Страница 48: ...all the air filter case cover in its original position and latch clamps i Close side left side cover and turn screw turn Spark Plug Cleaning and Replacement a Open left side cover by turning screw tur...

Страница 49: ...nd install it d Install the fuel tank cap Fuel Filter Check Replacement a Open left side cover by turning screw turn b Slide the hose clamp 2 away from the filter 3 and pull the fuel hose 1 off the fu...

Страница 50: ...es can be both dangerous to the operator and destructive to the equipment Inspect Fuel System Check for Leaks Inspect the fuel system and check for leaks on a regular basis Inspect the entire fuel sys...

Страница 51: ...muffler screen and spark arrester d Reinstall the spark arrester flame screen and sparker arrester bracket e Secure the spark arrester bracket with securing bolts Check DC Fuses a Remove the screw 1 a...

Страница 52: ...he product stating that a high altitude kit was installed and to remind you to re service the carburetor re jet when operating in lower altitude environments Maintenance Schedule 1 Initial replacement...

Страница 53: ...h a Engine speed too high a Bring generator to a qualified technician for adjustment Generator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Power Load Plannin...

Страница 54: ...s and will also void the warranty Engine speed Never attempt to modify the engine speed setting The engine speed is preset for safe and optimal performance of the generator If speed needs adjusting it...

Страница 55: ...an in compliance with all applicable local building and electrical codes If the generator is not isolated from the utility power system by such means generator output will back feed into the utility p...

Страница 56: ...ive harm Avoid inhalation of exhaust Smoking sparks Never smoke near the running generator and never operate near sources of sparks or flames Check output voltage Check output voltage to ensure the ge...

Страница 57: ...ge location Store the generator in a dry location away from sources of heat open flames sparks or pilot lights such as water heaters space heaters furnaces clothes dryers or other gas appliances EVEN...

Страница 58: ...Generator Exploded View 74006 Rev A 3 58...

Страница 59: ...Generator Exploded View 74006 Rev A 3 59...

Страница 60: ...ips head screw M5X16 2 112 800334 Or Kit 17 Fuel level sensor 1 113 Kit 17 Connecting plate 1 114 Spacer 4 115 Rubber grommet 4 Ref Part Description Qty 1 Kit 16 Bolt with flange M8x26 2 2 Flat washer...

Страница 61: ...133 800345 Or Kit 3 Receptacle L5 30R 1 134 800346 Or Kit 3 Receptacle 5 20R 2 135 800347 Or Kit 3 Receptacle L14 30R 1 136 800348 Or Kit 3 Receptacle 14 50R 1 137 Kit 3 Control panel 1 138 800349 Or...

Страница 62: ...Generator Kit Exploded View 74006 Rev A 3 62 Kit 1 Kit 2 Kit 4 Kit 5 Kit 6 Kit 7 Kit 8 Kit 9 Kit 10 Kit 11 Kit 12 Kit 13 Kit 14 Kit 15 Kit 16 Kit 17 Kit 18 Kit 3...

Страница 63: ...ssembly 1 6 800255 Battery bracket kit 1 7 800256 Front leg support kit 1 8 800257 Wheel kit 1 9 800258 Front muffler shield kit 1 10 800259 Carbon canister kit 1 11 800260 Engine mounting kit 1 12 80...

Страница 64: ...Engine Exploded View 800342 64...

Страница 65: ...embly 1 185 Kit 29 Crankcase cover gasket 1 186 800376 Bearing 1 187 Kit 23 Crankcase cover 1 188 800377 Flywheel 1 189 800378 Cap Dipstick 1 190 Kit 23 Bolt with flange M8x40 7 191 800379 Stay stud 1...

Страница 66: ...1 800268 Trigger kit 1 22 800269 Oil drain kit 1 23 800270 Crankcase cover kit 1 24 800271 Piston and connecting rod kit 1 25 800272 Valve rocker kit 1 26 800273 Valve cover kit 1 27 800274 Engine val...

Страница 67: ...paired is the sole decision of Powerhorse Powerhorse will not provide for replacement of complete products due to defective parts Any costs incurred due to replacement or repair of items outside of a...

Страница 68: ...hina WARNING This product can expose you to chemicals including gasoline engine exhaust which is known to the State of California to cause cancer and carbon monoxide which is known to the State of Cal...

Отзывы: