Summary of Important Safety Information for Operation
57
•
Malfunction during operation.
Immediately turn off the generator if any of the following conditions arise during operation:
o
Excessive change in engine speed, slow or fast
o
Overheating in load connecting devices
o
Sparking or arcs from generator
o
Loss of electrical output
o
Receptacle damage
o
Engine misfire
o
Excessive vibration
o
Flame or smoke
o
Abnormal noise
•
Adjusting / repairing
. Always turn off generator and remove spark plug(s) or spark plug wire(s) before working on the
generator to prevent accidental starting.
Safety
–
After use
•
Cool engine before storing.
Let engine cool for at least five minutes before storing. A hot engine can be a fire hazard.
•
Shut off fuel supply.
Make sure gasoline shut-off valve is in the OFF position.
•
Prevent accidental starting.
When generator is not in use, remove key from starter (key start engines) and secure in a safe
location, or remove spark plug(s) in order to ensure that generator cannot be started in a storage location or by untrained
persons.
•
Storage location.
Store the generator in a dry location away from sources of heat, open flames, sparks or pilot lights
–
such as
water heaters, space heaters, furnaces, clothes dryers, or other gas appliances
–
EVEN IF the generator’s gas tank is empty.
Residual gasoline could ignite.
•
Exercise regularly.
Exercise generator every four weeks to dry out moisture that accumulates in the windings. If generator
cannot be exercised on a regular basis, prepare generator for long term storage.
•
Periodic maintenance.
Perform periodic maintenance as directed in this manual to keep the generator in safe working
condition.
Safety - Inspection/Maintenance
Inspect and maintain your generator on a regular basis and repair as needed to keep it in safe working condition:
•
Turn off generator
. Always turn off generator and remove spark plug(s) or spark plug wire(s) before working on the engine or
generator to prevent accidental starting.
•
Replace guards / shields.
Make sure all guards and shields are replaced after servicing the generator.
•
Replacement parts.
If a part needs replacement, only use parts that meet the manufacturer’s specifications. Replacement
parts that do not meet specifications may result in a safety hazard or poor operation of the generator and will void the warranty.