Страница 2: ...18V Charging Port DC 12V USB Wireless Switch AC 100V 120V Output LCD Display AC 100V 120V Switch Wireless Charger DC 32V 95V Charging Port DC12V XT60 Output DC12V 5525 Output DC12V Auxiliary Output USB A USB C Ports Fuse AC 100V 120V Input E1500 PRO ...

Страница 3: ... 8V28Ah Protections Over Voltage Overheat Overload Short Circuit Self Recovery Temperature 0 45 32 F 113 F Charging 20 45 4 F 113 F Discharging AC Out 3 Pure sine wave 100V 120V Rated 2000W USB A 4 5V 2A 3 5V 9V 12V Max 18W 1 5V 9V 12V Max 18W 1 5V 9V 12V 20V Max 100W 1 USB C 2 DC 12V 10A Cigar Port Max 15W Wireless Charger DC 12V 30A XT60 Output GX16MF UPS SPECS AC100V 120V Max 15A AC100V 120V Ch...

Страница 4: ...tts If your device is more than 2000W The AC overload alarm will flash The power supply will stop working Temperature Alarm Icon E1500 PRO can power your devices at temperatures ranging from 20 45 If your working temperature is more than 45 the temperature alarm will flash the unit may stop working Time Indicator DC Out Temperature Alarm Battery Soc Voltage V AC Overload Alarm Charge Indicator Dis...

Страница 5: ...CHARGE TIME The solar charging time depends on weather conditions E1500 PRO has a built in MPPT charge controller that supports 32 95V 15A PV charging up to 800W 200W 1 9 10 Hours Recommended 400W 2 4 5 Hours Recommended 600W 3 3 3 5 Hours Recommended Anderson Solar Charging Cable 1 Pecron E1500 PRO 1 AC Charing Cable 1 MC4 Solar Charging Cable LSMC4 5GX16 1 Car Charging Cable 1 12V Alligator Clip...

Страница 6: ...ply Note Not applicable to specific applications that need transfer time under 8ms such as servers and workstations This UPS function only support protection for loads under 1600W we recommend that you only connect one device at a time to avoid overload and thus result in protection failure Pecron is not responsible for any devices damege or loss of data resulting from failing to follow the instru...

Страница 7: ...ircuit voltage of solar panel array must be than 95V otherwise it will damage the unit Do not wire more than two 36V AKA 24V solar panels in series or more than four 18V AKA 12V solar panels in series 18V 36V stands for Vmp the operating voltage of the solar panel 3 If you have any questions Please feel free to contact us support pecron com DC5521 Charging Port PV12V 18V 100W Maximum Input GX16MF ...

Страница 8: ...V MC4 Solar Charging Cable 1 pecron 200W 1 Using the pecron 200W 36V 1 200W to charge the E1500 PRO 18V is the operating voltage of the solar panels 36V is the operating voltage of the solar panels 36V 36V 72V Using the pecron 200W 36V 2 400W to charge the E1500 PRO MC4 Solar Charging Cable 1 pecron 200W 2 36V is the operating voltage of the solar panels ...

Страница 9: ...pen Circuit voltage exceeding 95V will damage the machine 36V 36V 36V 108V 36V 36V 36V 36V Using the pecron 200W 36V 3 600W to charge the E1500 PRO MC4 Solar Charging Cable 1 Y Branch MC4 Charging Cable 1 Y Branch MC4 Charging Cable 1 pecron 200W 3 NOTE This parallel charging cable sold separately 36V is the operating voltage of the solar panels ...

Страница 10: ...V 36V 36V 36V Using the pecron 200W 36V 4 800W to charge the E1500 PRO MC4 Solar Charging Cable 1 Y Branch MC4 Charging Cable 1 Y Branch MC4 Charging Cable 1 pecron 200W 4 NOTE This parallel charging cable sold separately 36V is the operating voltage of the solar panels ...

Страница 11: ...O Using the pecron 200W 36V 4 800W to charge the E1500 PRO MC4 Solar Charging Cable 1 Y Branch MC4 Charging Cable 1 Y Branch MC4 Charging Cable 1 pecron 200W 4 NOTE This parallel charging cable sold separately 36V is the operating voltage of the solar panels 72V ...

Страница 12: ...r that operate at less than 12V 30A Q3 Can the E1500 PRO be used as UPS A E1500 PRO supports UPS function with an automatic switchover time of 8 12ms Q4 How to calculate the E1500 PRO running time A Running Time Total Capacity 1450Wh 0 85 Depth of Discharge Loading Power Watts Q5 Can I use the E1500 PRO indoors and charge the E1500 PRO indoors A Yes the E1500 PRO is safe to use indoors FAQS PV GX1...

Страница 13: ...ith the User Manual or as authorized in Pecron s current product literature In compliance with laws and regulations Pecron reserves all rights for final explanation and to change these terms and conditions at any time without prior notice In the event that any revisions are made the revised terms and conditions shall be posted on our website immediately please visit our website to inform yourself ...

Страница 14: ...l off and violent vibration Please turn off the device immediately and stop using it in the event of major exterior impact Please fasten the unit firmly during transportation to avoid vibration and impact 11 In the event of immersing the device into the water accidently please place the unit in a safe open area and keep away from the unit until it is completely dry The dried unit should not be reu...

Страница 15: ...esignated battery recycling box This product contains batteries Batteries are dangerous chemicals and are strictly prohibited from being disposed of in ordinary trash For details please follow local laws and regulations on battery recycling and disposal 2 If the battery cannot be completely discharged due to the failure of the product itself please do not dispose of the battery directly in the bat...