Installation and operating manual
Page 61 of 95
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
In the event of problems with the clock or other inverter parts which are "not vital to
the operation of the inverter" (insofar as the unit is still capable of producing energy),
the type of problem will be indicated on the second line of the display, in the place of
the date and time.
Error messages are as follows:
- CLOCK FAIL indicates problems with the clock, it is necessary to call assistance
- BATTERY LOW battery is low
- ADJ. TIME appears when the unit is first turned on, or after the battery has been
replaced
- FAN FAILURE does not affect the correct operation of the inverter; replace the fan
at the first convenient opportunity
- MEMORY FAILURE: data collected can no longer be stored. For recovery, it is
necessary to call for assistance.
5.5.4
Main menu
Once the previous grid connection phases and electrical parameter checks have been
completed, other screens become available which allows us to monitor the inverter
operation from various viewpoints.
By pressing the ESC key (1st key from display) 3 new screens become accessible:
GENERAL QUESTIONS RELATING TO THE USE OF DISPLAY KEYS:
- Pressing the UP and DOWN keys, allows you to move from one entry to the next.
- Pressing the ESC key allows you to return to the previous session described in
chapter 5.5.3.
- Pressing ENTER allows you to access the corresponding sub-menu
Statistics
Settings
Information