Installation and operating manual
Page 49 of 95
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
The following table shows all the possible combinations of LED activation, with
reference to the operational state of AURORA.
Key:
LED on
LED flashing
LED off
Any of the aforementioned conditions
LED STATUS
OPERATIONAL
STATUS
NOTES
1
green:
yellow:
red:
AURORA self-
disconnection at night
Input voltage less than 90
Vdc for both inputs
2
green:
yellow:
red:
AURORA initialization,
loading settings and
waiting for grid check
It is in a transition status
needed for checking the
operating conditions
3
green:
yellow:
red:
AURORA is transferring
energy to the grid
The machine is operating
normally (search for the
maximum power point or
constant voltage)
4
green:
yellow:
red:
Anomaly detected in the
system isolation device
Leakage to the ground
detected
5
green:
yellow:
red:
Anomaly – fault!!!
The fault may an internal or
external anomaly, see the
report on the LCD display