Installation and operating manual
Page 54 of 95
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
Wrong Mode
//
E013
Wrong Input setting (Single instead of dual)
Wrong setting of inputs (single channel instead of
dual)
Over Temp.
//
E014
Overtemperature
Internal temperature too high
Cap. Fault
//
E015
Bulk Capacitor Fail
Bulk capacitor failure
Inv. Fail
//
E016
Internal error
Int.Error
//
E017
Internal error
Ground F.
//
E018
I leak fail
High leakage current or incorrect ground mode
Int.Error
//
E019
Ileak Sensor fail
Leakage current error
Int.Error
//
E020
Output relay self test fail
Output relay self test failed
Int.Error
//
E021
Output relay self test fail
Output relay self test failed
Int.Error
//
E022
Output relay self test timeout
Output relay self test failed
Int.Error
//
E023
Dc-Injection Error
Int.Error
//
E024
Internal Error
Int.Error
//
E025
Riso Low (Log Only)
Isolation resistance low (log only)
Int.Error
//
E026
Internal error
Int.Error
//
E031
Output relays fail
Output relays fault
Int.Error
//
E032
Unbalanced output currents
Output currents unbalanced
Fan Fail
W010
//
Fan Fail (No disconnection)
Fan failure (log only)
Int.Error
//
E033
Under Temperature
Internal temperature too low
IGBT not
ready
//
E034
Internal Error
Remote OFF
//
E035
Remote Off
Int.Error
//
E036
Vout Avg
Average output voltage out of range
Int.Error
W012
//
Clock Battery Low (No disconnection)
Clock battery low
Int.Error
W013
//
Clock Failure (No disconnection)
Clock does not work