Page
34
of
76
MICRO-0.25/0.3-I-OUTD-US-208/240
BCG.00612_AB
Part
3
Mounting and Wiring
Individual earth conductors for each MICRO inverter:
•
The conductor linking the assembly to the grounding distribution structure must be at least
6 AWG.
•
The conductor bonding the MICRO inverter to the structure must have a minimum cross
section of 8 AWG (maximum length 1m).
•
Ensure that the quality of the bond made between the conductor and the structure is secure.
Only a racking system that is certified for use as a grounding structure is permitted to use
this method.
Figure 3-3: Configurations for grounding the MICRO inverters
Incorrect grounding can cause physical injury, death or equipment malfunction
and increase electromagnetic interference.
Make sure that grounding conductors are adequately sized as required by safety
regulations.
Содержание AURORA MICRO-0.25-I-OUTD-US-208/240
Страница 1: ...THE MANUAL MICRO Model Number MICRO 0 25 I OUTD US 208 240 MICRO 0 3 I OUTD US 208 240...
Страница 2: ...AURORA MICRO Grid Tied Inverters MICRO 0 25 0 3 I OUTD US 208 240 Technical Manual...
Страница 31: ...Page 30 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 3 MOUNTING AND WIRING...
Страница 45: ...Page 44 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 4 OPERATIONS GUIDE...
Страница 51: ...Page 50 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 5 TROUBLESHOOTING...
Страница 60: ...Page 59 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 6 MAINTENANCE GUIDE...
Страница 64: ...Page 63 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 7 APPENDIX...
Страница 65: ...Page 64 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Part 7 Appendix 7 1 TECHNICAL DATA...
Страница 72: ...Page 71 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Part 7 Appendix Figure 7 9 Topographic Diagram...