Mounting and Wiring
3.2
ASSEMBLY INSTRUCTIONS
1
. Run the AC cable along the frame structure provided for installing the photovoltaic modules.
The cable must be compatible with the expected installation conditions,
particularly concerning the number of modules and their orientation (portrait or
landscape).
Legislation in force in the country of installation and the installed power will
determine the maximum number of MICRO inverters permitted for installation at
each AC cable section.
Do NOT exceed the maximum number of MICRO inverters permitted for
installation! (See technical data found in the Appendix, Part 7, of this manual.)
2
. Secure the MICRO inverter to the photovoltaic module frame with the logo side facing
downwards
.
Mark the approximate center of each photovoltaic module on the frame in order to facilitate
positioning.
3
. The inverter and photovoltaic modules must be connected
to an equipment grounding conductor in accordance with
the pertinent legislation in force in the country of
installation.
The inverter can be earth grounded using the connect clamp
secured to the chassis and an adequately-sized conductor.
There are two possible configurations for grounding the inverters shown below:
Содержание AURORA MICRO-0.25-I-OUTD-US-208/240
Страница 1: ...THE MANUAL MICRO Model Number MICRO 0 25 I OUTD US 208 240 MICRO 0 3 I OUTD US 208 240...
Страница 2: ...AURORA MICRO Grid Tied Inverters MICRO 0 25 0 3 I OUTD US 208 240 Technical Manual...
Страница 31: ...Page 30 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 3 MOUNTING AND WIRING...
Страница 45: ...Page 44 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 4 OPERATIONS GUIDE...
Страница 51: ...Page 50 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 5 TROUBLESHOOTING...
Страница 60: ...Page 59 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 6 MAINTENANCE GUIDE...
Страница 64: ...Page 63 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Technical Manual PART 7 APPENDIX...
Страница 65: ...Page 64 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Part 7 Appendix 7 1 TECHNICAL DATA...
Страница 72: ...Page 71 of 76 MICRO 0 25 0 3 I OUTD US 208 240 BCG 00612_AB Part 7 Appendix Figure 7 9 Topographic Diagram...