- 6 -
0600_GB-Power-Control_8537
GB
POWEr COnTrOL - OPErATiOn
Monitoring functions
The Power Control can monitor the following machine
functions: seed shaft, level, blower rpm, and calibration
flaps.
Press
“Special menu” key
• Menu base setting appears
- Select menu level using arrow keys
Monitoring
- Confirm with OK
Monitoring: Seed shaft
Whether the dosing shaft turns with the tail wheel is
monitored here.
• Select “Seed shaft” using arrow keys and confirm with
OK.
- Select “Seed shaft monitoring ON or OFF” using
arrow keys and confirm with OK.
• With “Seed shaft monitoring ON” the “Time-invariant
for seed shaft alarm” menu is called up.
- Enter time-variant with +/- keys
- Adjustable in 1 sec steps from 1 to 20 secs .
- Confirm with OK
Monitoring: Level
The tank content is acquired and monitored through
an analogue level measurement.
• Select “Level” using arrow keys and confirm with
OK.
- Select “Level monitoring ON or OFF” using arrow
keys and confirm with OK.
• With “Level monitoring ON” the “Minimum level” menu
is called up.
- Enter minimum with +/- keys
- Adjustable in 5% steps from 5 to 50% .
- Confirm with OK
Note!
Basically it is so:
If a monitoring
function is
deactivated, the
respective symbol
in the main menu
fades out and no
alarm will occur.