3 Starting the seed drill monitor for the first time
The Multitronic II seed drill monitor is activated by inserting the power supply plug in the
socket. A short horn signal indicates that the unit is active. The display is then active for
about two seconds, to show the type of machine in use:
<
> should be displayed for the
VITASEM
range.
<
>
should be displayed for the
AEROSEM
range.
<
>
should be displayed for the
TERRASEM
range.
If the wrong type of machine is displayed, the unit must be readjusted according to
machine type (see sect. 8). Before the seed drill monitor can operate correctly.
Displays can now be activated for drive speed, hectare meter, sowing shaft revolutions
or tramline circuit.
4 Multitronic II quick startup instructions for the VITASEM
4.1 Control panel of the Multitronic II seed drill monitor
Readout/Display (
1/1
), Function key Drive speed (
1/2
),
Sowing shaft revolutions (
1/3
), Hectare meter (
1/4
),
LED (
1/5
), Tramline (
1/6
),
Arrow keys (
1/7, A,V
),
F
-key (
1/8
)
4.2 Readout pushbuttons
The green keys are readout pushbuttons
Drive speed indicator (
1/2
)
Push once to readout drive speed
Readout Hectare meter (
1/4
)
Push once to display partial surface area hectare meter
Push twice to display total surface area hectare meter
To reset the partial surface area hectare meter, press both arrow
keys
A
and
V
for 2 sec.
To reset both hectare meters, press the two arrow
keys
A
and
V
for 10 sec.
Display Turnings (
1/3
)
Press once to display sowing shaft revolutions
Tramline cycle and Tramline rhythm indicator (
1/6
)
Use the arrow keys
A
or
V
to alter the tramline cycle manually.
Press twice to switch <
AUS
>
LED (1/5) ON = tramline active
LED (1/5) OFF = tramline inactive
4.3 Alarm messages
<
doSi
> = Sowing shaft monitoring alarm
<
FUEL
> = Hopper level monitoring alarm
2x
1
1
8
A
V
2
4
6
5
7