58
4000T
5.7 Checking and Adding Hydraulic Oil
1.
Make sure you observe all safety warnings
when working on the machine hydraulics.
2.
Always have machine situated on level
ground with the conveyors folded when
checking hydraulic oil levels or when adding
hydraulic oil.
3.
Check the hydraulic oil level gauge - If the
level is below the red mark on the gauge you
will need to add hydraulic oil.
4.
Hydraulic Oil Level Sensor - If the hydraulic oil
falls below this level the machine will shut
down. This will prevent damage to the
hydraulic components on the machine.
5.
To top up the hydraulic oil in the tank follow
these steps.
6.
Clean around the filler cap to prevent
contaminating the hydraulic oil. Fill the tank
to midway between the red and black lines on
the hydraulic oil level gauge.
7.
Clean up any oil spills in accordance with local
environmental regulations.
5.8 Changing Hydraulic Oil
1.
Make sure you observe all safety warnings
when working on the machine hydraulics.
2.
Always have machine situated on level
ground with the conveyors folded when
changing the hydraulic oil. It will be easier to
change the oil if it is at normal operating
temperature.
3.
Slowly unscrew the filler cap to release any
pressure build up.
4.
Place a suitable sized container under the
hydraulic tank and remove the bung to drain
the hydraulic oil.
5.
When all the hydraulic oil has been removed,
remove Suction filter. The Suction filter can
be removed by unscrewing the bolts that
attach the Suction filter to the hydraulic tank.
6.
Change the Suction element when changing
the hydraulic oil. Replace cover and tighten
bolts.
7.
Remove the bolts holding the return filter and
replace the return filter. Replace cover and
tighten bolts. (See section on Changing the
Return Line Filter)
8.
Refill the tank with the correct grade of
hydraulic oil to a level between the red and
black marks on the hydraulic oil gauge.
9.
Start the machine to rid the system of any air
and check oil levels again. If necessary, top
levels back up.
10.
When carrying out any maintenance work on
hydraulic components, turn the hydraulic shut
off valve lever to the closed position. This will
prevent excessive oil spillage. ALWAYS
remember to turn the valve to the open
position before starting machine. Failure to
do so will result in damage to the machine
hydraulic components.
Содержание 4000T
Страница 1: ...ii 4000T 4000T USER MANUAL...
Страница 7: ......
Страница 8: ...9 4000T...
Страница 20: ...4 0 0 0 T 21 P 006ENG P 008ENG P 009ENG P 010ENG P 011ENG P 014ENG P 016ENG P 018ENG P 027ENG P 029ENG P 036ENG...
Страница 24: ...4 0 0 0 T 25 2 3 Working Dimensions...
Страница 47: ...48 4000T Machine in working position Remove the locking pin from working position...
Страница 64: ...4 0 0 0 T 65...
Страница 70: ...4 0 0 0 T 71 Sprocket Alignment Nuts Turn clockwise moves drive Turn anticlockwise moves drive...
Страница 75: ...76 4000T Section 6 Electrical and Hydraulic Schematics...
Страница 76: ...77 4000T...
Страница 77: ...78 4000T...
Страница 78: ...4 0 0 0 T 79...
Страница 79: ...80 4000T...
Страница 80: ...4 0 0 0 T 81...
Страница 81: ...82 4000T...
Страница 82: ...4 0 0 0 T 83 SHREDDER PIPING...
Страница 83: ...84 4000T...
Страница 84: ...4 0 0 0 T 85...
Страница 85: ...86 4000T...
Страница 86: ...4 0 0 0 T 87...
Страница 87: ...88 4000T...
Страница 88: ...4 0 0 0 T 89...
Страница 89: ...90 4000T...
Страница 90: ...4 0 0 0 T 91...
Страница 91: ...92 4000T...
Страница 92: ...4 0 0 0 T 93...