Automatic boiler for wood pellets
Instructions for installation and operation
Note:
The work connected with cleaning the transport routes should be entrusted to a
specialized servicing company.
Important notice: Mains supply has to be disconnected from the wall socket or the
corresponding circuit breaker has to be reliably switched off in the switchboard, if any handling
takes place in the transport route.
After the reason for the STOP state has been removed, the automatic operation can be resumed by
depressing the key
AUTO/MANUAL
.
8.4 LACK OF PELLETS IN THE FUEL BIN
- will cause that the boiler will get burnt out. This condition is not indicated in any way on the
control unit (except for the heating water temperature drop indicated by thermometer) as it is not a
hazardous state.
The following has to be done in order to resume the operation:
- replenish fuel in the fuel bin (as per the system configuration)
- the feeder 1 has to be filled with fuel (see the chapter 6.6),
- the boiler has to be turned on (see the chapter 6.6).
8.5 ELECTRICITY SUPPLY INTERRUPTION
- boiler with electric ignition - automatic operation mode
Electricity supply interruption does not have any impact on further automatic operation of the boiler - every
electricity supply interruption triggers the electric ignition routine and thus further automatic operation is
started.
- boiler WITHOUT electric ignition - automatic operation mode
State of fuel burning in the boiler has to be checked after electricity supply interruption. Manual ignition has
to be performed (see chapter 6.6), if the fire has been extinguished.
9 DISPOSAL OF PRODUCT AFTER THE END OF ITS SERVICE LIFE
The product is made of materials the waste of which does not have any hazardous properties.
The following main kinds of waste will be generated after the end of the product's service life:
1. Steel exchanger, jacketing, feeders, bin
– waste code: 170405, category: O.
2. Heat insulation (ROTAFLEX, SIBRAL)
– waste code: 170604, category:O.
3. Ceramic grate, reflector and plates on door
– waste code: 170103, category:O.
Control unit with sensing and control elements
– waste code: 200136, category:O.
9.1 NATURAL PERSON
shall perform disposal of the product as follows:
1. Steel waste shall be sold to the nearest scrap-yard.
2. Heat insulation and ceramic parts shall be disposed of as mixed municipal waste.
3. The control unit with sensing and control elements is subject to return collection which does not take
place in the seller's plant but where the product has been purchased or at the manufacturer of the
boiler. Return collection is free of charge.
Do not remove the electric equipment as mixed municipal waste !