Automatic boiler for wood pellets
Instructions for installation and operation
/
The currently selected mode whether we will allow or deny moderate electric heating will be confirmed by
depressing the key
→
ENTER
. The following script will appear on the display unit
>
enabled
<
or
>
disabled
<
as per the just selected mode.
The programme of the control unit will return back to the menu
>
9. el. heating
<
.
It is possible to return back to the mode
MANUAL or AUTO by depressing the key
∩
ESC
or it is possible
to continue in selection of another menu with the cursor arrows
⇑
⇓
.
The block wiring diagram how additional heating coils are connected is on figure 4. The line wiring diagram
is on figure 18 and on figure 19.
Important notice: Mains supply has to be disconnected from the wall socket or the
corresponding circuit breaker has to be reliably switched off in the switchboard, if any handling
takes place on the electric parts of the boiler.
7 MAINTENANCE AND ATTENDANCE OF THE BOILER DURING OPERATION
As the structure of the product is totally modern and WOOD PELLETS with clearly guaranteed quality
values are exclusively used as fuel, the maintenance (attendance) of the product is very simply during
operation.
7.1 ATTENDANCE
1)
The level of
fuel in the bin
has always to be kept to be at least 10 cm over the functional
transport part of the ribbon flight. Irregular dosing may take place in case of further variation
(reduction) of the fuel level.
Note
: It is not possible to prescribe unambiguously the interval to replenish fuel. This interval
depends on:
-
bin size
-
average power output of the boiler within a specified given time interval
-
quality of the fuel used.
Assumed interval: ……………………………………… 1x a week
Note
: Large-volume bin can be installed to the boiler.
2) Ash pan emptying
Assumed interval: ……………………………………1x 2 weeks
(KP 10-20-11-21)
………………………………….. 1x 2 – 5 days
(KP 50)
Note
: When removing ash, check visually whether the ash does not contain excessive quantity
of unburnt fuel. If so, check whether the boiler woks in the recommended programme – i.e.
−
fuel feeding interval
−
idle interval
−
revolutions of fan
BE CAREFUL to always close tightly the door after every visual check of burning and
after ash removal!!! Open door is a cause of increased fire hazard and always deteriorate fuel
combustion processes.
29