Automatic boiler for wood pellets
Instructions for installation and operation
6.3 INSTALLATION OF THE CERAMIC EXTENSION GRATE
Individual parts of the ceramic extension grate are shown on the figure number 12.
KP 10, KP 11 KP 20, KP 21
KP 50
Figure number 12 – Parts of the ceramic grate
a) Function as such of these parts is as follows:
- increase turbulence of combustion products before entry to the exchanger
- use additionally the so far unburnt residues of the gaseous combustible on the ceramic burning surface
- direct the flow of combustion products through the exchanger.
b) This grate is installed into the boiler in such a way that individual parts (the left part, the right part) are
passed through the middle open part of settling bars and shifted tightly to the wall of the furnace (KP 10,
KP 11). As regards KP 20, KP 21, we continue in such a way that we will install the middle part of the grate
which has the shape of the letter X. KP 50 has these parts two in the middle part of the grate.
Ensure that the middle part is installed with even spaces towards the right and left part of the grate.
6.4 FITTING THE CERAMIC SHIELD
Figure number 13 – Ceramic shield
Insert the ceramic shield flatways across the furnace space and fit the part on holders over the door from
inside (see figure 1).
25