Polyprint S.A.
Polyprint S.A
– Texjet plus operation manual English V1.9
- 17 -
The maintenance tank must be reset before the ink level drops below 20%. It is
recommended to reset the tank after the ink level drops below 50%.
Maintenance tank chip resetting procedure
After resetting it, always empty the maintenance tank from the remaining ink
inside.
In order to reset the maintenance tank, the printer must be in “
Diagnostic mode
”. You cannot
reset the tank in normal mode. The procedure is as follows:
-Step 1
: Turn off the printer and remove the maintenance tank. Turn the printer on again in
diagnostic mode by pressing and holding the F1 button before pressing Power On. The printer
must start in diagnostic mode with the maintenance tank removed. Since the maintenance tank is
not inside, after initialization you should see the message “INSTALL MAINTENANCE
CARTRIDGE” on the top display.
-Step 2
: Empty the remaining ink and reset the chip using the chip Resetter. All the pins of
the Resetter should make contact with the tank’s chip. At first contact, the LED light should
blink red. Wait until the LED light turns green (green means the tank is reset).
-Step 3
: Insert the maintenance tank in the printer and press the “Eject” button once. If the
procedure is done properly, you should see a completely full maintenance cartridge.
-Step 4
: In order to proceed with the normal printing procedure, turn the printer off and
restart it in
normal mode
.
*If instead of “ready” message, the “NON-GENUINE” message appears at the panel display,
then follow the panel instructions. For more details refer to Panel instruction for “NON-
GENUINE” message bellow.