Troubleshooting
EASY WAY 201 is not responsible for the working of the remote control
The indicator ON/OFF does not light up after the power supply is connected.
Check the mains.
Check the supply cable.
Check the fuse.
The indicator DANGER emits light continuously. This signal indicates photocell failure.
Check the photocell setting.
Check the photocell power supply.
Check if photocells are present in automatic mode.
Check if the lamp voltage conforms to the power supply (230 V or 24 V for the solar system).
The indicator ON/OFF is flashing slowly.
Improper power: contact the Service department.
Excessive load: too strong wind or too heavy gate.
The indicator ON/OFF is flashing quickly.
Servomotor is overheating: wait for it to cool down.
Short circuit at the output(s) of the drive unit(s): contact the Service Department
Servomotors M1 and M2 are not activated or the direction of their operation is not correct.
Check the connection to the electricity supply
Check the extender between the two servomotors.
Check the servomotor cables; if necessary, exchange them (see page 18).
Limited operating range of the remote control.
Check the antenna cable.
Check the transmitter battery.
Environmental interference (overhead electricity pole, reinforced brickwork, etc.)
An external antenna is necessary.
After closing, the gate opens automatically.
Move away the bracket fastening the leaf slightly in the opposite direction to the hinges by using
the oblong holes.
After opening, the gate closes automatically.
Check the servomotor cables (see page 18).
Содержание EASY WAY201
Страница 1: ...DRIVE UNIT FOR SWING GATES EASY WAY 201 ...
Страница 9: ...9 GB 6 5 7 5 10 5 13 10 Preparation for assembly Necessary tools ...
Страница 37: ...37 GB ...
Страница 38: ...38 GB ...
Страница 39: ...39 GB ...
Страница 40: ...ul Deptak 17 04 956 Warszawa tel 48 022 872 00 91 93 fax 48 022 612 68 60 serwis polargos pl www polargos eu ...