Commands
Link Manager Manual
Description
If AutoAdd mode is enabled and the Link Manager receives a packet from a sensor
not already in the sensor table, it will add the new sensor to the table automatically.
When the Link Manager adds a sensor to the sensor table through AutoAdd mode it
assumes certain defaults for the parameters based on the type of sensor. You can
then modify these parameters using the “CS” command. The Link Manager will add
a new sensor to its table either whenever it receives a new sensor’s packet
[AutoAdd] or when it receives a new sensor’s packet sent in service mode [AutoAdd
(service)]. AutoAdd (service) gives you a little more control over building your
sensor table. You may need to push the service button to transmit the data and have
the sensor added. Using AutoAdd (service) you can add sensors to the table in a
particular order and segregate sensors between Link Managers. After you have
added the sensors you want the Link Manager to use, use the “AN” command to turn
off AutoAdd mode to prevent your setup from being changed.
The
auto off
time is used to specify a window of time where the AutoAdd mode is
enabled. After this time expires, the Link Manager will disable AutoAdd mode.
NOTE: For the “AT” and “AS” commands, in order for the Link Manager to
automatically add the sensor, the Link Manager must receive two packets from the sensor
no less than 5 seconds apart for 418 sensors. If “ATU” or “ASU” is used only one packet
is needed for the Link Manager to automatically add the sensor.
When a sensor is automatically added to the sensor table because of the AutoAdd
mode, Link Manager will assume certain defaults for the setup information for the
sensor. For the sensor name, Link Manager prefixes the default name with the row
number (sensor index) in the sensor table. Below is a table of the different sensor
types with the default setup information. The setup information is expressed as the
response to the CSR command.
AutoAdd Mode Default Entries
Sensor Model
Sensor
Description
Default Setup (response from the CSR
command)
Point Temp
Temperature
1,0700000005B3F528,13Temperature(A0.112
5,32.0000,degF,1)
Point Humid
Humidity/
Temperature
2,7D000000059A9328,2Humid_Temp(A1.00
0,0.000,%RH,0)(A0.1125,32.0000,degF,1)
Point Light
Light
3,230000000348A8328,3Light(A0.02440,0.00
00,%,2)
Point PIR
iButton
4.278C000000000000,4iButton(DN)
Point Analog
Analog
5,2A0000000B66C628,1Analog(A0.02440,0.
00000,%,2)
Point IR
Counter and
LSX
Dual Counter
with Dual
Discretes
6,000000000013D6F1,6Counter(SBlocked,Op
en,Closed,Error)(I1,0,count,0)(I1,0,open s,0)
AngData
Analog with
Data
8,DC00000001F15D27,5Analog_Data(A0.02
440,0.00000,%,2)(DY)
Point Analog
w/ Temp
Analog /
Temperature
9,A500000001E45227,6Analog_Temp(A0.02
440,0.00000,%,2)(A0.1125,32.0000,degF,1)
Discrete
Discrete Sensor
11,0110211220200100,16Discrete(Soff,on)
Point
Thermistor
Thermistor
Sensor
12,0101211220200100,1Thermistor(A0.1125,
32.0000,F,1,128)
16-bit Analog
Signed 16 bit
Analog sensor
13,010A211220200100,10Analog16(A0.0030
5,0.00000,%,2,0)
Point Counter
Temperature
Counter
Temperature
14,00000000000B1534,2CntTemp(STrans.,O
pen,Closed,Error)(I1,0,count,0)(A0.1