112
Commands
Link Manager Manual
Description
The “UM” command supplements the “U” and “CUM” commands.
Link Manager can be placed in a mode where packet information that it receives can
be repeated via Serial, Ethernet and/or Command Radio. Link Manager can forward
these packets as is (Standard or Extended) or convert the data to engineering units
and send it as a comma delimited record (Engineering).
Use the "UMR" command to get a listing of all the media's Pass-Thru modes. Use
the "UMS" command to set Pass-Thru mode for a media.
The Pass-Thru mode can also be changed using the “US”, “UE” or “UX” command.
Note: the Link Manager can change the Pass-Thru mode depending on the
parameters entered in the Pass-Thru Media Callout Table ("CUS" command). Use
the "UMR" command to read the current state of the media Pass-Thru mode.
See the section "Pass-Thru Mode" for more information.
Media
Designation
Physical
T
Ethernet
S (or 1S)
418/433 Mhz Receiver and RS485 port
2S
Serial Port
R
900 Mhz or 2.4 Ghz transceiver
Examples
Command: UMSTS
Response: UMSTS
Remarks: Set the passthru mode for the TCP/IP media to Standard Link
Manager will start sending asynchronous packets:
5428769D1B000000C30158B68E0A
11301020024F0C0029560232B334
11301020024F0C0029560232B334
Command: UM2SS
Response: UM2SS
Remarks: Set the passthru mode for the second serial port media to
Standard
Command: UMR
Response: UMR,1TS,1SN,2SS,1RN
Remarks: Read the passthru modes for all media. TCP/IP and the
second serial port are set to Standard.