Link Manager Manual
Appendix
123
Ethernet Firmware Download
Overview
The Link Manager firmware can be upgraded using the Ethernet connection. The
process takes less than a minute to complete on a LAN and 3 to 5 minutes on a WAN
or across the internet.
A Microsoft Windows PC utility is used to perform the firmware download. The
Link Manager must be accessible to the utility on the network LAN. Both the
TCP/IP Command Port (typically located at port 1000 by default) and the Ethernet
Download UDP port at 2000 must be accessible. Typically the Link Manager and
the utility must be located on the same LAN or accessible via a VPN connection. If
trying to upgrade the Link Manager from behind a firewall, changes to the firewall
setup may be needed to allow communications.
Preparation
1.
Confirm that communications with the Link Manager is possible.
2.
Obtain the IP address and the MAC address of the Link Manager. Send the
MAC address to your dealer. The dealer will generate a Security Code.
The Security Code is used to enable the Link Manager for Ethernet
firmware download mode. Once the function is enabled, all Link Manager
functions except for communications and command processing are disabled.
Use the Discover tool to obtain the IP and the MAC address or access the
System Actions page (ex:
http://192.168.1.55/sysact
). You can also
connect through one of the media and issue "IP" command to get the IP
address and "CDR" to obtain the MAC address.
3.
IMPORTANT: The Link Manager setup will be reset to factory
defaults except for the communication parameters.
After the Ethernet
firmware download process is completed, the Link Manager will have to be
reconfigured. Save the Link Manager setup before implementing the
Ethernet firmware download process or confirm that the Link Manager
setup has been saved in your application.
Procedure
1.
Obtain the IP address, MAC address and Security Code. (Obtain the
Security Code from your dealer).
2.
Confirm that the Link Manager setup parameters are saved by your
application
3.
Enter the Security Key (choose one of the following):
a.
Access the System Actions page (place “/sysact” after the IP
address in your browser: ex. “http://192.168.1.55/sysact”). Enter
the Security Code in the “Enter Upgrade Key” and click Submit.
b.
–Or- Use the Security Code and enable the Ethernet firmware
download function by sending the "11S" command.
11S
enabledtime
,
securitycode
Where