PUM_STR_091201_EN
9/30
0
Rail height
Trolley
Magnetic Grabber
®
Distance End stop/door
Lenght Blc
Mounting instructions;
1. Determine the installation height of the rail (measured from
the bottom of the rail).
2. Determine the recommended distance from the rubber end
stop to the door in the “installation table”.
3. Determine the recommended balancer locking cable (BLC)
length in the “installation table”.
Rail height
Distance End stop / door
Lenght Blc
Feet
m
Feet
m
Inch
cm
10
3
min
5,0
1,5
23,8
60,5
Recomended
5,5
1,7
26,9
68,4
max
6,0
1,8
30,4
77,2
Rail height
Distance End stop / door
Length Blc
Feet
m
Feet
m
Inch
cm
13
4
min
6,0
1,8
23,9
60,8
Recomended
6,5
2,0
26,7
67,9
max
7,0
2,1
29,7
75,4
Rail height
Distance End stop / door
Length Blc
Feet
m
Feet
m
Inch
cm
16
5
min
7,0
2,1
24,4
61,9
Recomended
7,5
2,3
26,9
68,4
max
8,0
2,4
29,6
75,2
Installation table:
Length Blc
4. After installation, fine tune the BLC and / or the rubber end
stop if the disconnection point is not 10” from the door.
If a disconnection point closer to the door is preferred, the
position of the end stop can be changed.
8. INSTALLATION
MAN_MAG_STR_TUV_SUD_180517/2_EN