PUM_STR_091201_EN
17/30
0
Max. 30m / 100'
Max. 10m / 33'
Max. 10m / 33'
Max. 10m / 33'
1
A
B
C
3
2
LIFTING THE RAIL
1. STR Rail
2. Vertical suspension
3. Horizontal suspension
Our recommendation is to lift a continuous length of rail up
to 30m / 100 ft max. with a max. distance between the lifting
points of 10m / 33ft.
Top suspension
a) Lift the rail according to the instruction and fix the bolts on
the RRTS lower bracket (A).
b) When the rail is in the right position fix the suspensions
with the bolts (B).
c) Fasten the suspensions by the sequrity bolt (C).
Side suspension
a) The legs is connected to the vertical support legs, using
couplings.
b) Adjust the rail both vertically and horizontally to get it level.
c) Tighten the couplings thoroughly and screw a safety bolt
(not only if required always do this), drill and screw a safety
bolt through the coupling and the support leg.
8.
INSTALLATION
ATTENTION
Always use approved lifting equipment. The lifting
equipment should only be operated by a certified
operator.
ATTENTION
NOTE! It is very important to lift the rail evenly to
avoid damage to the splicing sleeves.
WARNING
PRODUCT MAY CONTAIN SHARP EDGES
Use care when servicing unit.
Failure to do so could result in minor personal
injury.
MAN_MAG_STR_TUV_SUD_180517/2_EN