Control Words for SMS functions
•
System
•
Temp
•
Trigger
•
Status
•
On
•
Off
•
Auto
•
Evac
•
Battery
The Platypus Sprinkler Controller will respond to the above control words. The spelling is
critical, the case can be either upper or lower or a mixture of both. The control word should be
sent as a text message(SMS) to the Platypus Controller. The Platypus Controller will respond
with information relevant to the control word that was sent.
System
Text the control word "System" to the Platypus Controller. The Platypus Controller will respond
with a text which describes the current state of the Platypus Controller system.
for example:
Platypus Sprinkler Controller.
The current temperature at xxxxxxxx is xx.xc.
The trigger temperature is set at xx.
Devices connected to your Platypus Sprinkler Controller are:
Electric Motor
VFD
Water Solenoid 1
Water Solenoid 2
External Temperature Sensor
GSM Module
Temp
Text the control word "Temp" to the Platypus Controller. The Platypus Controller will respond
with a text which describes the current temperature where the Platypus Sprinkler Controller is
located.
for example:
Platypus Sprinkler Controller.
The current temperature at xxxxxxxx is xx.xc.
Status
Text the control word "Status" to the Platypus Controller. The Platypus Controller will respond
with a text which describes the current status of the Platypus Sprinkler Controller system.