background image

 
 

 

 

THH960  

 

User Manual

 

 (v1.6)

 

www.planckvisionsystems.com

 

47 

3.3.8

 

Power Save 

Tap the <Power Save> menu to set the automatic screen-off time setting and automatic 
shutdown time setting. 

 

 

Tap the automatic screen-off time and select the  idle  time before the camera enters 
sleep mode. 

 

Tap the power key to wake up the screen in sleep mode.

 

 

 

Tap  the  automatic  shutdown  time  and  select  the  idle  time  before  the  camera  will 
automatically shut down.

 

  

3.3.9

 

System 

Tap the <System> menu, to open a submenu that contains the following: 

 

 

<About> provides the following contents:

 

Model

 

Serial number

 

Содержание THH960

Страница 1: ...THH960 User Manual v1 6 www planckvisionsystems com i THH960 HIGH PERFORMANCE THERMAL CAMERA USER MANUAL...

Страница 2: ...in personal injury Used to alert you to situations which if not avoided could result in damage to the camera reduced camera performance data loss or other unpredictable results Used to highlight impor...

Страница 3: ...operate the camera in a temperature environment exceeding 50 C 122 F To prevent the potential danger of data loss please copy back up your camera s data to your computer regularly Do not open the came...

Страница 4: ...15 2 2 Startup 15 2 3 Shutdown 15 3 User interface 15 3 1 Home screen 15 3 1 1 On screen display OSD 15 3 1 2 Home screen menu 18 3 1 2 1 Overview of user interface icons 18 3 1 3 Temperature scale s...

Страница 5: ...3 2 2 3 Move and scale measurement region 31 3 2 2 4 OSD settings for regional measurements 31 3 2 2 5 Regional emissivity setting 32 3 2 2 6 Add a temperature difference measurement 32 3 2 2 7 Delet...

Страница 6: ...43 3 3 5 Auxiliaries 44 3 3 6 Network 45 3 3 7 Temperature range setting 46 3 3 8 Power Save 47 3 3 9 System 47 4 Radiometric image analysis 48 4 1 On camera analysis 48 4 2 IrAnalysisTools software 4...

Страница 7: ...nsit and metallurgy industries where preventative detection of temperature anomalies is required 1 2 Camera features 5 5 1080P high definition display Supports multiple display modes including thermal...

Страница 8: ...menu for shutdown restart or cancel options In the sleep mode state a short press is required to wake up the screen 6 LCD touch screen 7 Ambient light sensor 8 Viewfinder switch 9 Programmable button...

Страница 9: ...tures can be taken in either a non radiometric jpeg format or radiometric JPEG format see 3 2 3 1 The radiometric format supports temperature examination and user annotations voice and written Still p...

Страница 10: ...directly into the laser beam the laser beam may cause eye injury 3 Focus ring for thermal image 4 Shoulder strap attachment point 1 3 5 Top view 1 Infrared thermal imaging lens 2 Visible camera 3 Fla...

Страница 11: ...llows PC access to memory card and internal storage of images and videos 2 Operation guide 2 1 Preparation before operation 2 1 1 Charging The battery can be charged with an external charger or throug...

Страница 12: ...ure that the metal tabs at the bottom of the battery align with the metal tabs inside the battery compartment and push the battery inward to complete the battery installation Be sure to use original b...

Страница 13: ...Confirm that the camera is turned off Step 2 Press the change lens button next to the lens Step 3 Rotate the front of the lens counterclockwise to remove the old lens Step 4 Align the red dots on the...

Страница 14: ...barrel according to the needs of the working condition When holding the camera with the right hand be sure to support the lens barrel with the left hand at the same time This will greatly reduce the...

Страница 15: ...screen is displayed 2 3 Shutdown Shutdown can be done manually or automatically Manual shutdown requires a long press of the power button to turn off the camera Tap the system settings icon enter the...

Страница 16: ...f 4 Temperature range setting The high column icon represents the high temperature measurement range 100 700 C The low column icon represents the low temperature measurement range 40 150 C 5 Temperatu...

Страница 17: ...14 Temperature alarm indicator Displayed when an temperature measurement alarms is active please refer to 3 1 5 15 Color bar Color spectrum assigned to the range of temperatures between minimum and m...

Страница 18: ...Alarm settings sets alarm type and alarm thresholds 4 System settings 5 Thermal Visual display mode switch 6 Capture button 7 Image gallery 8 Measure Capture main menu 9 Global measurement parameters...

Страница 19: ...com tnc downloads thh960 3 1 3 Temperature scale setting Tap the temperature scale bar setting icon to toggle between Automatic and Manual settings In automatic mode the upper and lower limits of the...

Страница 20: ...erature alarm modes are supported Above below between outside and temperature difference While there is an active alarm condition the icon flashes on screen An audible alert and or alarm location disp...

Страница 21: ...p dial to select the Below setting Step 3 Tap Lower threshold from the submenu and scroll to the desired setting Step 4 Tap the screen outside of the alarm menu to complete the settings 3 1 5 3 Betwee...

Страница 22: ...croll the popup dial to select the first temperature measurement Step 4 Tap T2 and scroll the popup dial to select the second temperature measurement Step 5 Tap T and scroll the popup dial to set the...

Страница 23: ...ore steps Tap the icon to change global measurement settings see 3 2 1 Tap the icon to create or modify local measurement regions see 3 2 2 Tap the icon to change the thermal image display mode see 3...

Страница 24: ...pplicable to the file format type is tapped to enter the image analysis interface please refer to Section 4 for detailed description is tapped to view the time title type size resolution latitude and...

Страница 25: ...s the capture mode selection menu 3 2 3 The icon opens the image display mode selection menu 3 2 4 The icon opens the operational settings menu 3 2 5 The icon opens the camera s system settings menu 3...

Страница 26: ...y material type selection using the right dial An abbreviated reference table of emissivity values is also provided in Section 6 Step 4 Tap the screen outside of the menu area to complete the setting...

Страница 27: ...temperature Ambient temperature refers to the environment temperature where the camera and the measurement surface are located To set the ambient temperature Step 1 Tap the ambient temperature settin...

Страница 28: ...between the target and the camera lens The measurement distance must be correctly set for accurate temperature measurements To set the measurement distance Step 1 Tap the measurement distance setting...

Страница 29: ...the temperature of any external lens or IR window used in front of the lens To set the external optical window temperature Step 1 Measure the temperature of the external lens or IR window Step 2 Tap...

Страница 30: ...oint 3 2 2 1 Add a temperature measurement region There are 5 types of temperature measurement regions that can be added point line rectangle ellipse and center spot Use the following steps to add a n...

Страница 31: ...d on the touch screen or by using the direction ring see 1 3 1 item 12 Step 3 Re enter the Measure Capture submenu as needed and tap the icon to adjust the selected region size Adjust the region size...

Страница 32: ...material type selection using the right dial An abbreviated reference table of emissivity values is provided in Section 6 The direction ring and selection button see 1 3 1 item 12 can also be used to...

Страница 33: ...egion and 2 all which deletes all temperature measurement regions Deletion of an individual temperature measurement region is accomplished with the steps Step 1 Select the region of interest using the...

Страница 34: ...n in either a non radiometric jpeg format or radiometric JPEG format The radiometric format supports temperature examination and user annotations voice and written Still pictures can also be taken in...

Страница 35: ...rtest interval is 1 second and the longest interval is 59 minutes and 59 seconds The maximum number of captured pictures is 1000 3 2 4 Display mode The available display modes are thermal visible pict...

Страница 36: ...1 Tap the picture in picture icon appearing in the display mode submenu Step 2 Use the Level dial to adjust the visibility of the thermal image to the desired state Step 3 Use the Alignment dials to a...

Страница 37: ...gh 3 2 5 9 3 2 5 1 OSD display hide switch Is used to display hide the On Screen Display OSD information on the live screen 3 2 5 2 Flashlight on off switch Is used to turn on off the camera s flashli...

Страница 38: ...e A periodic flat field correction is performed automatically during normal camera operation The home screen displays Calibrating during FFC 3 2 5 7 Laser pointer Press and hold the icon to turn the l...

Страница 39: ...the icon to enter the main system setting interface of the camera The various system settings are described in 3 3 3 3 System settings Tap the icon to enter the system setting interface of the camera...

Страница 40: ...60 User Manual v1 6 www planckvisionsystems com 40 Tap Language to choose the language Tap Time zone to select the time zone corresponding to the location of the camera Tap Date to modify the system d...

Страница 41: ...system time The system time can be accurately set to seconds Tap Date Format to select the system date format Tap Time Format to modify the system time format 3 3 2 Temperature and distance units Tap...

Страница 42: ...ius C Kelvin K and Fahrenheit F settings Tap Distance Unit to select between meter m and feet ft 3 3 3 On Screen Display Tap On Screen Display to select information to be displayed at the bottom of th...

Страница 43: ...he resolution enhancement When on the thermal image is displayed with 4 times the sensor resolution DDE Digital Detail Enhancement supports three settings low medium and high The higher the dynamic im...

Страница 44: ...ge Storage allows users to select internal storage or external SD card storage options Storage Space Displays the internal storage and SD card usage capacity Unmount SD Card Unmounts the SD card and r...

Страница 45: ...nual temperature width switch FFC and snapshot video mode switch Location Services Toggles on off the location services Volume Used to adjust the sound volume Automatic Screen Brightness Toggles on of...

Страница 46: ...rophone on the camera provides voice input and the Bluetooth headset provides voice output from the camera Tap the Portable hotspot key to enter the hotspot management menu Tap the enable key on the t...

Страница 47: ...e automatic screen off time and select the idle time before the camera enters sleep mode Tap the power key to wake up the screen in sleep mode Tap the automatic shutdown time and select the idle time...

Страница 48: ...diometric picture or video is captured secondary analysis can be performed on camera prior to saving or subsequent to saving 4 1 On camera analysis Subsequent radiometric image analysis can be perform...

Страница 49: ...or CD ROM to the computer Step 2 Start the analysis software Step 3 Using a USB data cable or SD card reader copy the image of the IRimg folder in the camera or SD card to the common directory on the...

Страница 50: ...an be played back in the image gallery or using the IrAnalysisTools PC software This icon is the voice annotation key Tap it to add a voice annotation to the radiometric file When using this function...

Страница 51: ...box the text input soft keyboard will automatically pop up at the bottom of the touch screen Step 3 After entering the text information tap the save key to automatically save the text information to t...

Страница 52: ...cles under the sunlight Do not disassemble or squeeze batteries and battery packs If the camera is stored for a long time please remove the battery Please use the original power adapter to charge the...

Страница 53: ...relevant laws and regulations and other needs Planck Vision Systems may update this manual and the updated content will be reflected in the new product version without prior notice Responsibility Stat...

Отзывы: