CUBE MC features a terminal board cover. Inside this cover are the terminals which the
installer must connect up to:
- The mains power line
- The RS 485 data line to the PC (optional).
The connector block, accessible through the front panel opening, is already wired up to the
CUBE MC components, according to the block diagram shown below.
1- Remove the right terminal
board cover.
2- Connect the cables as
shown in the diagram.
3- Close the terminal board
cover box again.
NOTE:
The parts indicated in the diagram are the only connections to be made by the customer:
- Connection to power mains.
- RS485 output to PC (OPTIONAL).
EN
13
(Translated from Italian)
The installer should carry out a plug/socket connection for a quick sectioning of the
electric system in case of failures.
! ATTENTION
For CUBE MC commissioning, no further power connections are required.
All the electronic components housed in the MC BOX are already wired up and factory
tested.
It is therefore NEVER necessary for the installer or station manager to open the MC BOX
except to replace the protection fuses housed on the I/O card (see photo below).
! ATTENTION