MANUFACTURER'S DETAILS AND AFTER-SALES SERVICE

P

MANUFACTURER:

DOCUMENT TYPE:

EDITION: 

PRODUCT:

MODEL:

CONFORMITY:

TECHNICAL SUPPORT:

PIUSI S.p.A.

General description and instructions
for its installation, activation,
use and maintenance

Bullettin M0104D EN - Rev. 1

Diesel fuel dispenser for private use with meter

All the models of the CUBE MC range,
with single-phase/three-phase
mechanical/electronic meter,
with various voltages/frequencies

CE MARK

(see Declaration of conformity, page 4)

Provided by the Service Departments
of our Authorized Resellers

The  information  contained  in  this  manual  is  provided  by  the  Manufacturer,  who  reserves  the
right to make changes without prior notice.

EN

25

(Translated from Italian)

Содержание cube mc

Страница 1: ...Bulletin M0104D EN Rev 1 CONSUMER PUMPS CONSUMER PUMPS ENGLISH USE AND MAINTENANCE MANUAL ...

Страница 2: ...2 EN ...

Страница 3: ...ANICAL INSTALLATION H4 HYDRAULIC CONNECTIONS H4 1 MAXIMUM LENGTH OF THE SUCTION PIPES H5 ELECTRICAL CONNECTIONS I COMMISSIONING I1 ELECTRICAL POWER SUPPLY I2 WETTING THE PUMP I3 STATION CONFIGURATION I4 DISENGAGING THE MC SYSTEM I5 FIRST PRIMING I6 METER CALIBRATION L DAILY USE L1 FUEL DISPENSING M ROUTINE MAINTENANCE M1 OPENING AND CLOSING THE CUBE MC M2 PUMP AND PIPES M3 DISPENSER PIPE AND NOZZL...

Страница 4: ...the equipment described below PIUSI S p A Via Pacinotti c m z i Rangavino 46029 Suzzara Mantova Italy EC DECLARATION OF CONFORMITY Suzzara 29 12 2009 is in conformity with the legal provisions indicated in the directives The documentation is at the disposal of the competent authority following motivated request at Piusi S p A or following request sent to the email address doc_tec piusi com The per...

Страница 5: ...ispenser stops whenever fuel has not been dispensed for more than 2 minutes Smoking prohibited When operating the dispenser and in particular during refuelling do not smoke and do not use open flame Electrical precautions There are dangerously high voltages inside the unit Only qualified and authorized technical personnel are allowed to open the dispenser Service Service of the dispenser must be p...

Страница 6: ...he positioning fixing and installation phase Once the packaging has been removed the station must always be kept in vertical position Packaging parts cardboard wood cellophane etc must be placed in specific containers and not left lying around or within reach of children as these represent a potential risk hazard They must be disposed of according to the regulations applicable in the country of us...

Страница 7: ... of the various models providing information on electrical and mechanical installation first start up operations daily use This manual DOES NOT cover other aspects such as configuration and operation of the Control system For these aspects refer to the specific manuals which accompany each station model For the installer s convenience all supplied manuals are grouped together in an envelope This c...

Страница 8: ...ION 230 50 VERSION 110 60 CUBE MC 230 V 50 Hz 4 2 A 900 W 2800 rpm IP55 YEAR 2008 Read instruction M0103 M0104 CODE f0059400 LOT NUMBER 0000001 CERTIFIED COMPANY UNI EN ISO 9001 PIUSI S P A SUZZARA MN ITALY Qmax 72 l min Pmax 3 bar 75 db S1 COSØ 0 92 Cond 12 5 m F CUBE MC 110 V 60 Hz 5 5 A 550 W 2785 rpm IP55 YEAR 2008 Read instruction M0103 M0104 CODE f0059400 LOT NUMBER 0000001 CERTIFIED COMPANY...

Страница 9: ...otection IP 55 according to EN 60034 5 86 standard self ventilated single phase For further details refer to the relevant manuals indicated in the summary table of paragraph E1 The K600 3 Pulser meter features a measurement system with high precision oval gears designed for accurate fuel metering These have a sturdy die cast aluminium structure and are complete with inlet suction filter They are e...

Страница 10: ...N PLATE The maximum acceptable variations from the electrical parameters are VOLTAGE 5 FREQUENCY 2 The IDENTIFICATION PLATE shows maximum ABSORBED POWER in Ampères with respect to which the power protection appliances required by applicable standards not supplied with the station must be sized The maximum absorbed power refers to intended use operation DISPENSING OF DIESEL FUEL with power supply w...

Страница 11: ... Observe the distances and maximum differences in level between the station and the tank Securely fasten the casing to the ground on a horizontal surface Station positioning determines the following parameters which distinguish each installation Hp Priming height Ls Total length of the suction pipe from the foot valve to the station expressed in metres To ensure correct station operation the follo...

Страница 12: ...on pipe must resist a pressure of at least 10 bar and must be of a diameter NOT LOWER THAN 1 1 4 The tubing must be suitable to functioning under backpressure Use tubing and accessories suitable for use with diesel fuel Materials that are not suitable for use with diesel fuel can cause damage to the pump harm people and cause pollution Any curves in the suction pipes must be of the widest radius p...

Страница 13: ...x again NOTE The parts indicated in the diagram are the only connections to be made by the customer Connection to power mains RS485 output to PC OPTIONAL EN 13 Translated from Italian The installer should carry out a plug socket connection for a quick sectioning of the electric system in case of failures ATTENTION For CUBE MC commissioning no further power connections are required All the electron...

Страница 14: ...re the main connections and the fuses to be replaced by skilled service technicians only KEY 1 Key reader I Button 2 Display card 3 CPU card 4 Keyboard 5 I O card 6 Jumper 7 Electrical boxes Translated from Italian ...

Страница 15: ...t there must be a small quantity of diesel fuel inside the impeller chamber The pump is supplied adequately wetted and ready for use If however the installer considers the pump to be totally dry perhaps due to prolonged storage he will have to wet it as he thinks best Every CUBE MC station can be adapted to the specific requirements of the station manager To do this the MC control system must be C...

Страница 16: ... control lever is moved to OFF position Operate the lever of the automatic nozzle keeping the spout inside an adequate container or the same suction tank Air will first of all come out of the nozzle and then DIESEL FUEL will gradually begin to flow I5 FIRST PRIMING EN 16 Translated from Italian The jumper is only accessible by opening the front panel and is positioned as shown in the photo In this...

Страница 17: ...ctory proceed to CALIBRATE THE METER according to the instructions in the specific manual I6 METER CALIBRATION EN 17 Translated from Italian Differences of up to 1 10 of a litre affecting the dispensing of 20 litres of fluid fall within the guaranteed accuracy of 0 5 ATTENTION To correctly check accuracy always keep to the following instructions Use a precision sample container featuring a graduat...

Страница 18: ...s soon as the control lever is moved to ON position while it switches off as soon as the control lever is moved to OFF position No further manual operation is required to start or stop the pump In the case of the simplest configuration no optional data required the fuel dispensing procedure is the following 1 Enter PIN CODE If the MC recognises an authorised code it displays the following messages...

Страница 19: ... that the hoses are in perfect condition not damaged refer to the Panther M0042 and K600 M0147 manual Lower the display cover Loosen the 2 screws on the right side marked by the arrows Open the inspection side of the CUBE MC To reclose it perform these steps in reverse order M1 OPENING AND CLOSING THE CUBE MC M2 PUMP AND PIPES EN 19 Translated from Italian If there is a power cut or the pump stops...

Страница 20: ... dedicated M0103 manual provided CUBE MC features a number of filters having different functions The inspection and cleaning or replacement of each filter is crucial to ensure The protection of the various station components pulser pump nozzle Station performance remains high over the years maximum flow rate Protection of the engines using the dispensed diesel fuel PROBE HOLE AUTOMATIC STOP SPOUT ...

Страница 21: ...is filter is fitted downstream of the pump suction filter it does not require regular inspection and cleaning Should the need arise however and or in case of special maintenance it can be cleaned as described in the PULSER MANUAL after removing the roof of CUBE MC if necessary by means of its relevant upper screws see exploded view pos 14 The meter pulser is a carefully made and assembled high pre...

Страница 22: ...heck the seals of the connections Calibrate the meter see M0147 Check that the voltage is not more than 5 below the nominal voltage Lower the CUBE MC with respect to the tank or increase the diameter of the tubing Use shorter tubing or of greater diameter Raise the suction pipe Refill the tank Remove any dirt and or blockages from the automatic stop probe hole Check the seals of the connections an...

Страница 23: ... FOR VERSION 110V 60Hz In order to change the fuses inside the electronic board panel we suggest proceeding as follows Interrupt power to the CUBE MC Remove the cover of the MC BOX panel Replace the burnt out fuses Close the panel again Restore power to the CUBE MC EN 23 Translated from Italian ...

Страница 24: ...EN 24 CUBE MC SPARE PARTS O Translated from Italian ...

Страница 25: ...v 1 Diesel fuel dispenser for private use with meter All the models of the CUBE MC range with single phase three phase mechanical electronic meter with various voltages frequencies CE MARK see Declaration of conformity page 4 Provided by the Service Departments of our Authorized Resellers The information contained in this manual is provided by the Manufacturer who reserves the right to make change...

Страница 26: ...EN 26 NOTES ...

Страница 27: ...27 EN NOTES ...

Страница 28: ...Authorized reseller s stamp M0104D EN Rev 1 330 South Maple Street Corona Ca USA PH 951 531 8870 FAX 951 531 8827 www fueltransfer com ...