Additional information
15
109
En
Troubleshooting
Inco
rr
ect o
p
e
r
ations a
r
e often mistaken fo
r
t
r
ouble and malfunctions. If you think that the
r
e is something w
r
ong with
this com
p
onent, check the
p
oints below. Sometimes the t
r
ouble may lie in anothe
r
com
p
onent. Investigate the othe
r
com
p
onents and elect
r
ical a
pp
liances being used. If the t
r
ouble cannot be
r
ectified even afte
r
exe
r
cising the checks
listed below, ask you
r
nea
r
est Pionee
r
autho
r
ized inde
p
endent se
r
vice com
p
any to ca
rr
y out
r
e
p
ai
r
wo
r
k.
Note
• If the unit does not o
p
e
r
ate no
r
mally due to exte
r
nal effects such as static elect
r
icity disconnect the
p
owe
r
p
lug
f
r
om the outlet and inse
r
t again to
r
etu
r
n to no
r
mal o
p
e
r
ating conditions.
Power
Symptom
Remedy
The
p
owe
r
does not tu
r
n on.
• Make su
r
e that the
p
owe
r
cable is
p
lugged in to an active
p
owe
r
outlet.
• T
r
y disconnecting f
r
om the
p
owe
r
outlet, then
p
lugging back in.
The
r
eceive
r
suddenly switches
off o
r
the PHASE CONTROL
indicato
r
blinks.
• Check that the
r
e a
r
e no loose st
r
ands of s
p
eake
r
wi
r
e touching the
r
ea
r
p
anel o
r
anothe
r
set of
wi
r
es. If so,
r
e-attach the s
p
eake
r
wi
r
es, making su
r
e the
r
e a
r
e no st
r
ay st
r
ands.
• The
r
eceive
r
may have a se
r
ious
pr
oblem. Disconnect f
r
om the
p
owe
r
and call a Pionee
r
autho
r
ized
inde
p
endent se
r
vice com
p
any.
Du
r
ing loud
p
layback the
p
owe
r
suddenly switches off.
• Tu
r
n down the volume.
• Lowe
r
the 63 Hz and 125 Hz equalize
r
levels in the
Manual MCACC setup
on
p
age 46.
• Switch on the digital safety featu
r
e. While holding down
HOME MENU
on the f
r
ont
p
anel,
pr
ess
STANDBY/ON
to set this
r
eceive
r
to the standby mode. Use
/
to select
D.SAFETY
OFF
,
and then use
/
to select
1
o
r
2
(select
D.SAFETY
OFF
to deactivate this featu
r
e). If the
p
owe
r
switches off even with
2
switched on, tu
r
n down the volume. With
1
o
r
2
on, some featu
r
es may be
unavailable.
The unit does not
r
es
p
ond
when the buttons a
r
e
pr
essed.
• T
r
y switching the
r
eceive
r
off, then back on again.
• T
r
y disconnecting the
p
owe
r
cable, then connect again.
AMP ERR
blinks in the dis
p
lay,
then the
p
owe
r
automatically
switches off. The
MCACC
blinks and the
p
owe
r
does not
tu
r
n on.
• The
r
eceive
r
may have a se
r
ious
pr
oblem. Do not t
r
y switching the
r
eceive
r
on. Contact a Pionee
r
autho
r
ized inde
p
endent se
r
vice com
p
any fo
r
hel
p
.
FAN STOP
blinks in the
dis
p
lay, then the
p
owe
r
automatically switches off and
DIGITAL VIDEO SCALER
indicato
r
blinks.
• Something is obst
r
ucting the fan. Remove the obst
r
uction and t
r
y switching the
r
eceive
r
back on.
If the fan is still not wo
r
king, o
r
you can’t
r
emove the object, un
p
lug the
r
eceive
r
f
r
om the wall and
call a Pionee
r
autho
r
ized inde
p
endent se
r
vice com
p
any.
• The fan is malfunctioning. Un
p
lug the
r
eceive
r
f
r
om the wall and call a Pionee
r
autho
r
ized
inde
p
endent se
r
vice com
p
any.
OVERHEAT
o
r
AMP
OVERHEAT
flashes, the
p
owe
r
tu
r
ns off, and the blue indicato
r
at the cente
r
of the
r
eceive
r
flashes.
• Allow the unit to cool down in a well-ventilated
p
lace befo
r
e switching back on.
• Wait at least 1 minute, then t
r
y tu
r
ning the
p
owe
r
on again.
Dis
p
lay blinks
12V TRG ERR
.
• An e
rr
o
r
has a
r
isen in the 12 V t
r
igge
r
jacks. Reconnect accu
r
ately then tu
r
n the
p
owe
r
back on.
SCLX81_71.book 109 ページ 2008年7月25日 金曜日 午後3時1分