Special installation (Wall hanging (vertically wall-hanging equipment))
3.4.10 Wall hanging (vertically wall-hanging equipment)
This display is designed to accommodate a range of wall installations. For this type of installation, carefully consider all
installation specifics before beginning work, since these factors can significantly affect the temperature of the air
surrounding the display. Please observe the following requirements:
1
Use
plate metal that keeps all single holes clear
and has dimensions no larger than those given in the following
table.
2
Leave adequate ventilation space between the wall and the display.
3
Mount a metal plate with sufficient strength at each of the four positions indicated in the following figure (four-
point stopping).
Mounting the display on the wall involves danger. Be sure to take double safety measures.
4
Recommended ambient operating temperatures are listed in the following table. Operate the display within this
temperature range.
5
The surface of the wall should closely approximate a perfectly flat plane. Keep deformation pressures on the
display, such as twisting and bending, at or below 1 mm.
Do not block this area on either the top or the bottom.
40mm
Do not block this area to the left or right.
40mm
A
Wall
75mm
694 mm (center indicated)
75mm
75mm
75mm
Clearance A to the wall
100 mm or more
50 mm or more
Less than 100 mm
0 to less than 50 mm
Ambient operating temperatures
0 to 35 °C
0 to 30 °C
Cannot be used.
Remarks
Содержание PDA-4001
Страница 5: ...5 Ver 2 1 Features ...
Страница 19: ...19 Ver 2 1 Installation procedure ...
Страница 53: ...53 Ver 2 1 Special installation Horizontal connections ...
Страница 63: ...63 Ver 2 1 Mounting standard metal fixtures PDK 4001 ...
Страница 69: ...69 Ver 2 1 Mounting standard metal fixtures PDK 4002 ...
Страница 75: ...75 Ver 2 1 Mounting standard metal fixtures PDK 4004 ...
Страница 89: ...89 Ver 2 1 Mounting standard metal fixtures PDK 4006 ...
Страница 101: ...101 Ver 2 1 Mounting standard metal fixtures Precautions for installing the optional speaker ...