42
<Ver. 2.1>
Special installation (Installation under the floor (using the PDM-4001))
3.4.9 Installation under the floor (using the PDM-4001)
• If protective glass or similar material is used, the multi-installation fixture (PDM-4001) shown in the following figure is
very useful.
600 mm or more
Intake
Exhaust
B
B
C
C
Protective glass surface
|
Looking in the direction of the arrow (see the next page)
If the display is used in the closed space, observe the following conditions in the above environment:
A
≥
20 mm (clearance between the protective glass and PDP)
B
≥
100 mm (clearance between the PDP and side wall)
C
≥
50 mm (clearance between the PDP and side wall)
In the closed space, keep the temperature at 30 °C or less.
A + 50 mm
or less
A
60 mm
or less
Exhaust fan
Flow of air from the air conditioner
Intake port
Tempered glass, etc. (permeable)
Multi-installation fixture (PDM-4001)
B
B
C
291mm
A + 50 mm
or less
60 mm or
less
Exhaust port
600 mm or more
Floor
Exhaust
C