12
<Ver. 2.1>
Installation conditions
3.2.2 Calculating calorific values
Estimate the maximum power consumption per device as 400 W plus a safety margin. Most of the power consumed
is converted to heat, so power consumption is roughly equivalent to generated heat.
1) Conversion to calories
[W]
×
0.86 = [kcal/h]
Calorific value per display
400
×
0.86 = 344 [kcal/h]
2) Conversion to British thermal unit (BTU)
[W]
×
3.41 = [B.t.u./h]
Calorific value per display
400
×
3.41 = 1256 [B.t.u./h]
Air flows out through five of the ventilation holes and flows in through the other holes. For special installations, such
as wall-hanging or embedding, additional restrictions apply concerning operating temperature. See “3.4 Special
installations”.
3.2 Installation conditions
3.2.1 Radiation
This display comes with multiple ventilation holes for efficient radiation of heat.
Avoid blocking any of these holes.
Ventilation holes are indicated by arrows in the following drawing.
Five fans
Side slits
Side slits