127
<Ver. 2.1>
5.3.2 Interface
1) Connector
D-sub 9 pin
2) Pin assignment
3) Baud rate
4800 bps (possible settings include 1200, 2400, 9600, and 19200 bps)
Notes: Set this value so that the machine's baud rate equals the PC baud rate.
4) Data format
Start
: 1-bit
Data
: 8-bit
Parity : 0 (no parity)
Stop
: 1-bit
5) Connection
6) Protocol
From PC to plasma display
Note) For the following commands, only the first command is valid. Other commands are ignored.
Example 1)
STX
PON
AJY
CNT
ETX
Example 2)
STX
POF
PON
ETX
Example 3)
STX
IN2
AJY
CNT
ETX
(1) When commands are sent serially (one by one).
STX
COMMAND
ETX
STX=02h ETX=03h
COMMAND 3-Byte (ASCII)
(2) When groups of commands are sent
STX
COMMAND
COMMAND
COMMAND
ETX
(3) In the case of commands followed by numbers in the 0-255 range
STX
COMMAND
ARGUMENT
ETX
ARGUMENT : 3-Byte (ASCII)
COMPUTER (PC-98)
Plasma display
COMPUTER (IBM PC)
Plasma display
RXD 3
2 TXD
RXD 2
2 TXD
TXD 2
3 RXD
TXD 3
3 RXD
CTS 5
8 CTS
CTS 8
8 CTS
GND 7
5 GND
GND 5
5 GND
* Third-party D-sub 9P-D-sub 25P conversion cables are available commercially.
Send the PON and POF commands one by one.
(Allow 3 seconds or longer between commands.)
Send input switching commands (IN 1 - 4) and “AJY”
commands separately. (Allow at least 1.5 seconds after
input switching commands (IN 1 - 4) are set before
sending any other commands.)
Up to three commands may
be sent at a time.
note)
PIN NO.
Symbol
Signal NAME
2
TXD
Transmitted Data
3
RXD
Recieved Data
8
CTS
Clear To Send
5
GND
Signal Ground
Straight cable
Outer control by RS232C
Содержание PDA-4001
Страница 5: ...5 Ver 2 1 Features ...
Страница 19: ...19 Ver 2 1 Installation procedure ...
Страница 53: ...53 Ver 2 1 Special installation Horizontal connections ...
Страница 63: ...63 Ver 2 1 Mounting standard metal fixtures PDK 4001 ...
Страница 69: ...69 Ver 2 1 Mounting standard metal fixtures PDK 4002 ...
Страница 75: ...75 Ver 2 1 Mounting standard metal fixtures PDK 4004 ...
Страница 89: ...89 Ver 2 1 Mounting standard metal fixtures PDK 4006 ...
Страница 101: ...101 Ver 2 1 Mounting standard metal fixtures Precautions for installing the optional speaker ...