Special installations (Wall hanging)
3.4.2 Wall hanging
This display may be wall-mounted. Since this form of mounting affects ventilation patterns inside, observe the following
requirements:
1
When mounting plate metal, avoid blocking any ventilation holes.
Use plate metal of the size indicated in the
following drawing.
2
Provide space for adequate ventilation between the wall and the display.
3
Use plate metal having sufficient strength (with a safety factor of approximately four), and attach at four points (4-
point mounting) as shown below. Since wall installations involve certain hazards, always follow double-safety
procedures.
4
The following table lists proper operating temperatures. Use the display within the listed range of outside air
temperature.
5
Keep deformation of the display to 1 mm, including twisting and bending.
Clearance A to the wall
100 mm or more
50 mm or more
Less than 100 mm
0 to less than 50 mm
Operating temperatures
0 to 40 °C
0 to 40 °C (Animation)
0 to 35 °C (Still)
0 to 30 °C
Remarks
When this display is used with its back surface close to the
wall, interior temperatures will rise. The inner sensor is
activated at approximately 30 °C. Luminance decreases by 30%
and fan speed increases.
Do not block this area at either the top or bottom.
40mm
Do not block this area at either the left or right.
40mm
A
75mm 75mm
Wall
694 mm (center indicated)
75mm 75mm
Содержание PDA-4001
Страница 5: ...5 Ver 2 1 Features ...
Страница 19: ...19 Ver 2 1 Installation procedure ...
Страница 53: ...53 Ver 2 1 Special installation Horizontal connections ...
Страница 63: ...63 Ver 2 1 Mounting standard metal fixtures PDK 4001 ...
Страница 69: ...69 Ver 2 1 Mounting standard metal fixtures PDK 4002 ...
Страница 75: ...75 Ver 2 1 Mounting standard metal fixtures PDK 4004 ...
Страница 89: ...89 Ver 2 1 Mounting standard metal fixtures PDK 4006 ...
Страница 101: ...101 Ver 2 1 Mounting standard metal fixtures Precautions for installing the optional speaker ...