Technical Details Order No. 570824-570828
Operating Manual PSEN sg2c
1003267-EN-04
71
Times
570824
570826
570828
Test pulse duration, safety
outputs
450 µs
450 µs
450 µs
Switch-on delay
after UB is applied
1,1 s
1,1 s
1,1 s
Inputs typ.
15 ms
15 ms
15 ms
Inputs max.
20 ms
20 ms
20 ms
Actuator typ.
90 ms
90 ms
90 ms
Actuator max.
120 ms
120 ms
120 ms
Delay-on de-energisation
Inputs typ.
15 ms
15 ms
15 ms
Inputs max.
20 ms
20 ms
20 ms
Actuator typ.
30 ms
30 ms
30 ms
Actuator max.
260 ms
260 ms
260 ms
Supply interruption before
de-energisation
20 ms
20 ms
20 ms
Simultaneity, channel 1
and 2 max.
7 ms
7 ms
7 ms
Environmental data
570824
570826
570828
Temperature of metal sur-
face at ambient temperat-
ure: 25 °C
40 °C
40 °C
40 °C
Ambient temperature
In accordance with the
standard
EN 60068-2-14
EN 60068-2-14
EN 60068-2-14
Temperature range
-20 - 55 °C
-20 - 55 °C
-20 - 55 °C
Storage temperature
In accordance with the
standard
EN 60068-2-1/-2
EN 60068-2-1/-2
EN 60068-2-1/-2
Temperature range
-25 - 70 °C
-25 - 70 °C
-25 - 70 °C
Climatic suitability
In accordance with the
standard
EN 60068-2-78
EN 60068-2-78
EN 60068-2-78
Humidity
93 % r. h. at 40 °C
93 % r. h. at 40 °C
93 % r. h. at 40 °C
EMC
EN 55011: class A, EN
61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN
61000-4-5, EN 61000-4-6,
EN 61000-4-8
EN 55011: class A, EN
61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN
61000-4-5, EN 61000-4-6,
EN 61000-4-8
EN 55011: class A, EN
61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN
61000-4-5, EN 61000-4-6,
EN 61000-4-8
Vibration
In accordance with the
standard
EN 60068-2-6
EN 60068-2-6
EN 60068-2-6
Frequency
10 - 55 Hz
10 - 55 Hz
10 - 55 Hz
Amplitude
1 mm
1 mm
1 mm
Shock stress
In accordance with the
standard
EN 60068-2-27
EN 60068-2-27
EN 60068-2-27
Acceleration
30g
30g
30g
Duration
11 ms
11 ms
11 ms