The device can be switched in series with all safety switches from Pilz. In the connection
example, the safety switch guard locking device is activated / deactivated via access re-
quest (X1-5). The maximum switching current of the solenoid is present only while switch-
ing the solenoids for about 50 ms. The solenoids of the safety switches are switched with a
low time offset of ca. 1 s, to avoid power surges at the evaluation device.