Overview
Operating Manual PSEN sg2c
1003267-EN-04
7
2
Overview
2.1
Scope of PSEN sg2c Unit
}
Safety switch
}
Handle unit with actuator
}
Colour covers for illuminated buttons
}
Pin for escape release
2.2
Unit features
}
Safe guard locking (only for revolving gates and swing gates)
}
Safe interlocking (position monitoring)
}
Transponder technology
}
2 safety inputs for series connection of multiple safety switches
}
2 safety outputs
}
Guard locking element keeps the safety gate from being opened unintentionally
}
Detection of broken bolt tongue and broken guard locking element
}
Handle unit with locking lever to attach padlocks as a restart interlock
}
Auxiliary release for opening the safety gate, when the plant's voltage is switched off
}
Escape release for fast manual release of the guard locking in emergency situations
from within the danger zone (revolving gates and swing gates)
}
Suitable for left and right hinged safety gates
Note: The handle unit PSEN sg2c actuator is only suitable for revolving gates and
swing gates.
}
Plug-in spring-loaded terminals
}
LED indicator for:
–
Supply voltage/fault
–
Gate locked
–
State of the hazardous machine
–
Request to stop the machine
–
State of the inputs
–
Bolt tongue engaged
}
Depends on device type
–
Various control elements, for example integral E-STOP pushbutton, section stop
pushbutton, key-operated pushbutton, key switch...
–
Coding:
- coded
- uniquely coded
See section entitled Device types