Installation
Operating Manual PSEN sg2c
1003267-EN-04
34
}
Insert the escape or auxiliary release pin [1] into the safety switch and push it right to
the back. The swivel piece [2] must be maintained in a vertical position, safe from the
escape or auxiliary release pin. Screw the ball head on to the escape release pin.
Check the escape release for ease of movement. Fold down the cover on the escape
release
②
and lock into position.
}
Screw the ball handle [4] into the handle unit, lock the bolt tongue of the handle unit [5]
into position in the actuator guide plate. (See section entitled
Initial installation of handle
unit [
36]
INFORMATION
If the escape or auxiliary release pin is not inserted into the swivel piece
correctly, commissioning of the PSENsgate will be aborted and an error
code will be issued.
[2]
[3]
[4]
[5]
[1]