Installation
Operating Manual PSEN sg2c
1003267-EN-04
32
}
Align actuator guide plate and safety switch. Please note the distance between the
handle unit and the safety switch (see chapter entitled
Adjustment [
43]
).
}
Fix actuator guide plate and safety switch with M5 - DIN EN ISO 4762 - socket head
cap screws (hexagon socket, e.g.: Bossard: BN3 (without shaft), galvanised blue,
torque setting Ma = 5 Nm). Use washer M5 - DIN125A (e.g.: Bossard: BN 715, galvan-
ised blue, dimension: 10 x 5.3 x 1) for this.
The fixing screws on the safety switch are located under the cover of the escape re-
lease. Use an appropriate screw adhesive (e.g. Loctite 2700) to protect the socket head
cap screws from working loose.
WARNING!
Risk of manipulation of the safety device if the actuator guide plate is not
secured permanently!
If the actuator guide plate is not secured permanently, there is a risk that the
safety function will be defeated through manipulation. Depending on the ap-
plication, serious injury or death may result.
– If the actuator guide plate is installed using only the unprotected
screws [1] accessible from the side, then one-way screws must be
used for manipulation protection.
– If the screws used under the bolt tongue [2] are protected against
manipulation, then this is not necessary.
[1]
[2]