Installation
Operating Manual PSEN sg2c
1003267-EN-04
33
}
Unscrew the pressure screw [1] from the housing and remove the rubber seal [2].
}
Thread the cable through the correctly oriented pressure screw and the rubber seal, re-
move the blind insert if necessary.
}
Remove the countersunk screws [3] on the housing cover for the connection terminals
and slowly remove the housing cover [4]. In doing so, the spring mechanism moves the
cover of the escape release upwards.
}
Unscrew the strain relief plate [5].
}
Connect and insert connection terminals.
}
Position cable and screw on the strain relief plate (torque setting Ma 0.9 Nm +/- 0.1 (8
in-lbs)).
}
Fix housing cover with screws (torque setting Ma 1.7 Nm +/- 0.1 (15 in-lbs)).
}
Move the rubber seal along the cables and position it in the housing.
}
Screw pressure screw on the thread.