![Pilz PSEN op2B-2-050/1 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/pilz/psen-op2b-2-050-1/psen-op2b-2-050-1_operating-manual_1556675058.webp)
Technical details
Operating Manual PSEN op2B/1 Series
1003357-EN-02
58
Environmental data
630806
630807
Airgap creepage
Pollution degree
2
2
Protection type
In accordance with the standard
EN 60529
EN 60529
Housing
IP65
IP65
Mechanical data
630806
630807
Material
Top
Aluminium
Aluminium
Dimensions
Height
1.053 mm
1.353 mm
Width
35 mm
35 mm
Depth
41,2 mm
41,2 mm
Weight
4.500 g
5.400 g
11.1
Safety characteristic data
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
Operating
mode
EN ISO
13849-1:
2008
PL
EN ISO
13849-1:
2008
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2008
T
M
[year]
2-ch. OSSD
PL c
Cat. 2
SIL CL 1
1,00E-08
SIL 1
–
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are
not
identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.